CHAPTER 5 PERIODIC MAINTENANCE
5-2
(4) Install the toner cartridge into the new
drum unit until it locks into place,
indicated by a click. When the toner
cartridge is installed correctly, the lock
lever is lifted automatically. (Fig. 5-2)
(5) Install the new drum unit into the printer.
Check that the printer is turned on, the
front cover is open and the Drum and
Alarm LEDs illuminate.
Fig. 5-2
(6) Press the control panel button until all the LEDs are on. (The LED turns on in sequence
from top to bottom.)
The drum page counter is reset
.
(7) Close the front cover, and check that the Drum LED is now off.
!
CAUTION:
•
For best performance, use only genuine Brother toner. The product should only be used in
a clean, dust-free environment with adequate ventilation..
•
Only unpack a drum unit immediately before you need to install it into the printer. If an
unpacked drum unit is subjected to excessive direct sunlight or room light, the unit may be
damaged.
•
Handle the drum unit and toner cartridge carefully. If toner scatters on your hands or
clothes, wipe or wash it off with cold water immediately.
•
Do not reset the page counter when replacing the toner cartridge only.
1.2
Toner Cartridge
Toner low:
The Data and Alarm LEDs blink once every five seconds.
Toner empty:
The Data and Alarm LEDs blink once every second.
Life expectancy:
3,000 pages/standard toner cartridge
6,000 pages/high-capacity toner cartridge
(When printing A4- or Letter-size paper at 5% print coverage)
NOTE:
There are many factors that determine the actual toner life, such as temperature, humidity,
type of paper that you use, the number of pages per print job, etc.
<Replacement Procedure>
(1) Open the front cover, and pull out the
drum unit from the printer.
(2) Place the drum unit containing the old
toner cartridge on a flat, horizontal
surface, and remove the toner cartridge
from the drum unit while pushing the
lock lever down with your right hand.
(3) Unpack the new toner cartridge, and
gently rock it from side to side 5 or 6
times keeping it horizontal. (Fig. 5-3)