6. USING THE OPERATION PANEL
BAS-341F,342F
17
6-2. Using the floppy disk
<Compatible types of floppy disk>
Data t ype
No. of stitches
programmed
Data resolution
Disk
Format
Write
enabled
300E type
(300F type)
20,000 stitches per
pattern 100 pattern
Up to a maxi-mum
of 360,000 stitches
0.05 mm/pulse
Yes
Tajima embroidery
data
50,000 stitches per pattern
0.1 mm/pulse
2HD
1.44 MB
No
Old 300A type
4,000 stitches per
pattern 10 patterns
Up to a maximum of
40,000 stitches
0.1 mm/pulse
Yes
Old 300 data
2,000 stitches per
pattern 10 patterns
Up to a maximum of
20,000 stitches
0.2 mm/pulse
2DD
Automatically
formatted
No
• The above four types of data can all be read, but when writing to disk, all data is automatically converted to 300F,
300E data when writing to 2HD disks and 300A data when writing to 2DD disks.
• When using a 2HD disk, use a disk which has been pre-formatted as a 1.44 MB disk. (The programmer can be used
to format these disks. Refer to the programmer instruction manual for details.)
• TFD embroidery data can be embroidered after it has been converted by the programmer to BAS-300F and BAS-
300E data.
• Restriction on using 2DD floppy disks.
In order to maintain compatibility with the old 300A series, the following restrictions have been placed on the use of
the new functions which have been added to the E series.
Restricted function
A series (2DD)
F, E series (2HD)
Applicable
command
Resolution
0.1 mm/pulse
0.05 mm/pulse
Low-speed conversion
2 types
(400 and 1,200 revolutions)
4 types (400, 600, 800and
1,200 revolutions)
[668] L
[669] L
Split function
during embroidering
Not available
Available
[220] L
[230] L
Needle down stop for split
Not available
Available
[221] L
[231] L
Expansion option output
Not available
Available