Confidential
9 - 1 0
Error Code
(Hex)
Symptom Probable
Cause
Solution
BC Not
used.
CIS defective
Replace the scanner cover
(scanner unit).
BD
Black level data error.
Main PCB defective
Replace the main PCB.
BE
Scan starting edge detection
error. (Not used.)
BF-CF Not
used.
D0-DF
Modem error.
Main PCB defective
Replace the main PCB.
E0-E3 Not
used.
E4
Out of recording paper.
(Not used.)
E5 Not
used.
E6
Write error in EEPROM.
Main PCB defective
Replace the main PCB.
E7 Not
used.
CIS defective
Replace the scanner cover
(scanner unit).
E8
Data scanning error during
transmission.
Main PCB defective
Replace the main PCB.
E9 Not
used.
Document front sensor
actuator caught on the
surrounding parts
Correct the surrounding
parts on which the
actuator caught.
Sensor PCB defective
Replace the sensor PCB.
EA
Document removed at phase
B.
Main PCB defective
Replace the main PCB.
EB-ED Not
used.
EE-F2 Not
used.
F3, F5
Internal software error.
(Not used.)
F4 Not
used.
F6
PC interface error. (Not used.)
F7-FE Not
used.
FF
Memory management error.
(Not used.)