Confidential
9-24
M-8
Fixing unit failure
Possible cause
Step
Check
Result
Remedy
Poor
thermistor
harness
contact
1
Is the contact of connector
CN19 on the main PCB
good?
No
Reconnect the connector.
Blown thermal
fuse
2
Remove the fixing unit and
measure the resistance
between the thermostat. Is
it open circuit?
Yes Replace the fixing unit.
Yes Replace the fixing unit.
Thermistor
assembling
failure
3
Is the thermistor installed
properly?
No
Reinstall the thermistor
properly.
Halogen
heater lamp
failure
4
Remove the fixing unit and
measure the resistance of
the halogen heater lamp. Is
it open circuit?
Yes Replace the halogen heater
lamp.
Heater harness
connection
failure
5
Is the heater harness
connector connected to the
low-voltage power supply
PCB and fixing unit
secure?
No
Reconnect the connectors
securely.
NOTE:
•
This problem will be cleared if leaving the printer power ON for ten minutes.
M-9
Main PCB failure
Possible cause
Step
Check
Result
Remedy
Main PCB
1
Is it possible to print the
test page with the method?
No
Replace the main PCB.
Software bug
2
Does this problem appear
when printing specific data
or printing under a specific
environment?
Yes Inform the Brother office of the
used specific data, printer
condition and system
environment.