WSW08 ; NOTE: - Page 275

Brother DCP7010 User Manual

2014 Dodge Charger SRT Owner Manual

Table of Contents

ALLFB SERVICE MANUAL
TABLE OF CONTENTS
background image

 App. 

4-12 

Confidential

 

WSW08 

(Dial tone setting 2)

 

Selector 

No. 

Function 

Setting and Specifications 

1st dial tone detection time 
length 

No.  1  2  3 

 

0 0 0 : 

  50 

ms 

 

0 0 1 : 

  210 

ms 

 

0 1 0 : 

  500 

ms 

 

0 1 1 : 

  800 

ms 

 

1 0 0 : 

  900 

ms 

 

1 0 1 : 

  1.5 

sec. 

 

1 1 0 : 

  2.0 

sec. 

 

1 1 1 : 

  2.5 

sec. 

 

Time-out length for 1st and 
2nd dial tone detection 

No.  4  5 
 

0  0  :  10 sec. 

 

0  1  :  20 sec. 

 

1  0  : 15 sec. 

 

1  1  :  30 sec. 

Detection level of 1st dial 
tone and busy tone before 
dialing 

No.  6  7  8 

 0 

0  0  :   -21 dBm 

 0 

0  1  :   -24 dBm 

 0 

1  0  :   -27 dBm 

 0 

1  1  :   -30 dBm 

 1 

0  0  :   -33 dBm 

 1 

0  1  :   -36 dBm 

 1 

1  0  :   -39 dBm 

 1 

1  1  :   -42 dBm 

NOTE:  

The WSW08 is not applicable in those countries where no dial tone detection is supported,  

e.g., U.S.A. 

  Selectors 1 through 3:  1st dial tone detection time length 

Upon detection of the 1st dial tone for the time length set by these selectors, the machine starts  
dialing. 
This setting is effective only when selectors 1 through 3 on WSW05 are set to "1,1,1." 

  Selectors 4 and 5:  Time-out length for 1st and 2nd dial tone detection 

These selectors set the time-out length for the 1st and 2nd dial tone detection so that the machine  
waits dial tone input for the specified time length and disconnects itself from the line when no dial  
tone is inputted. 