App.
4-5
Confidential
WSW03
(PABX* mode setting)
Selector
No.
Function
Setting and Specifications
1
CNG detection when sharing a
modular wall socket with a
telephone
0: A
1: B
2
|
4
Detection time length of
PABX* dial tone, required
for starting dialing
(Not used.)
No. 2 3 4
0 0 0 :
50
ms
0 0 1 : 210
ms
0 1 0 : 500
ms
0 1 1 : 800
ms
1 0 0 : 900
ms
1 0 1 : 1.5
sec.
1 1 0 : 2.0
sec.
1 1 1 : 2.5
sec.
5
CNG detection when sharing
a modular wall socket with a
telephone
0: A
1: B
6
7
Dial tone detection in
PABX*
(Not used.)
No. 6 7
0 0 :
No
detection
(3.5 sec. WAIT)
0 1 :
No
detection
(5 sec. WAIT)
1 0 :
No
detection
(7 sec. WAIT)
1 1 :
Detection
(Frequency only)
8 Not
used.
* PABX: Private automatic branch exchange
NOTE:
Selectors 2 through 4, 6 and 7 are not applicable where no PABX is installed.
Selectors 1 and 5: CNG detection when sharing a modular wall socket with a telephone
These selectors determine whether or not the machine detects a CNG signal when a line is
connected to a telephone sharing a modular wall socket with the machine. Upon detection of CNG
signals by the number of cycles specified by these selectors, the machine interprets CNG as an
effective signal and then starts FAX reception.
Selector
No. 1 No. 5
Cycle
0 (A) 0 (A)
0 (A) 1 (B)
1 (B) 0 (A)
1 (B) 1 (B)
0.5 cycle
1.0 cycle
1.5 cycles
2.0 cycles
Selectors 2 through 4: Detection time length of PABX dial tone, required for starting dialing
(Not used.)
Upon detection of the PABX dial tone for the time length set by these selectors, the machine starts
dialing.
These selectors are effective only when both selectors 6 and 7 are set to "1" (Detection).