 App. 

4-7 

Confidential

 

  Selector 4:  Dual tone detection sensitivity in ICM recording 

Setting this selector to "1" increases the tone detection sensitivity in ICM recording. 

  Selectors 5 and 6:  Earth time length for earth function (Not used.) 

These selectors set the short-circuiting time length of the telephone line (La or Lb) to ground. 
This setting is effective only when the earth function is selected for the 

R

 key by using the  

function switch. 

  Selectors 7 and 8:  Break time length for flash function 

These selectors set the break time length. 
This setting is effective only when the flash function is selected for the 

Search/Speed Dial

 key by  

using the function switch. 

 

 

WSW05 

(1st dial tone and busy tone detection)

 

Selector 

No. 

Function 

Setting and Specifications 

1st dial tone detection 

No. 1  2  3 
 

0  0  0 

  3.5 sec. WAIT 

 

0  0  1 

  7.0 sec. WAIT 

 

0  1  0 

10.5 sec. WAIT 

 

0  1  1 

14.0 sec. WAIT 

 

1  0  0 

17.5 sec. WAIT 

 

1  0  1 

21.0 sec. WAIT 

 

1  1  0 

24.5 sec. WAIT 

 

1  1  1 

Detection (Without WAIT) 

Max. pause time allowable for 
remote ID code detection 

0 :  2 seconds 

1:   1 second 

 

Busy tone detection in auto-
matic sending mode 

No. 5 6 
 0 

:  No 

detection 

 

0  1  : 

Detection only after dialing 

 1 

:  No 

detection 

 

1  1  : 

Detection before and after dialing

Busy tone detection in auto-
matic receiving mode 

0 :  Yes 

1:  No 

8 Not 

used. 

 

NOTE:

  Selectors 5 through 7 are not applicable in those countries where no busy tone detection is  

supported. 