Selectors 1 through 3: Redial/Pause key setting and 2nd dial tone detection ; Selectors 4 through 6: Detection of international tone- Page 273

Brother DCP7025 User Manual

2014 Dodge Charger SRT Owner Manual

Table of Contents

ALLFB SERVICE MANUAL
TABLE OF CONTENTS
background image

 App. 

4-10 

Confidential

 

 

 

 

 

Selectors 1 through 3:  Redial/Pause key setting and 2nd dial tone detection 

Selectors  
1 2 3 

 

0  0  0 

No WAIT is inserted even if the 

Redial/Pause

 key is pressed. 

0 0 1 
0 1 0 
0 1 1 
1 0 0 

If you press the 

Redial/Pause

 key during dialing, the machine will insert 

WAIT as defined in the above table. 
If the 

Redial/Pause

 key is pressed repeatedly, the machine inserts the 

specified WAIT multiplied by the number of depressions.  It applies also in 
hook-up dialing. 

1 0 1 
1 1 0 
1 1 1 

When these selectors are set to "1, 0, 1": 
Each time you press the 

Redial/Pause

 key in dialing, the machine will wait 

for the 2nd dial tone to be sent via the communications line regardless of 
pulse dialing or tone dialing. 
When these selectors are set to "1, 1, 0": 
If you press the 

Redial/Pause

 key in pulse dialing, the machine will first wait 

for the 2nd dial tone to be sent via the communications line.  After that, 
pressing the 

Redial/Pause

 key will cause the machine to insert a WAIT of 3.5 

seconds.  In tone dialing, the machine will insert a WAIT of 3.5 seconds. 
When these selectors are set to "1, 1, 1": 
If you press the 

Redial/Pause

 key, the machine will first wait for the 2nd dial 

tone to be sent via the communications line regardless of pulse dialing or tone 
dialing. After that, pressing the 

Redial/Pause

 key will cause the machine to 

insert a WAIT of 3.5 seconds. 
(In those countries where no dial tone detection function is supported, setting 
these selectors to "1, 0, 1," "1, 1, 0," or "1, 1, 1" inserts a WAIT of 3.5 
seconds.) 

 

 

 

 

 

Selectors 4 through 6:  Detection of international tone

 

 

 

 

Upon detection of the 2nd dial tone for the time length specified by these selectors, the machine  
starts dialing. 
This setting is effective only when the 2nd dial tone detection function is activated by selectors 1  
through 3 (Setting 101, 110, or 111). 
This function does not apply in those countries where no dial tone detection function is supported. 

  Selector 7:  No. of 2nd dial tone detection cycles 

This selector sets the number of dial tone detection cycles required for starting dialing. 

  Selector 8:  Allowable instantaneous interrupt during reception of 2nd dial tone 

This selector sets the allowable instantaneous interrupt period that should be ignored during  
reception of the 2nd dial tone. 