App.
4-33
Confidential
WSW29
(Function setting 7)
Selector
No.
Function
Setting and Specifications
1
|
3
Compression threshold level
for voice signals inputted via
the telephone line in the built-
in TAD operation
No. 1 2 3
0
0
0
: -47.0
dBm
(A)
0
0
1
: -48.5
dBm
(B)
0
1
0
: -50.0
dBm
(C)
0
1
1
: -51.5
dBm
(D)
1
0
0
: -53.0
dBm
(E)
1
0
1
: -54.5
dBm
(F)
1
1
0
: -56.0
dBm
(G)
1
1
1
: OFF
(H)
4
|
6
Compression threshold level
for voice signals inputted via
the handset in the built-in TAD
operation
No. 4 5 6
0
0
0
: -44.0
dBm
(A)
0
0
1
: -45.5
dBm
(B)
0
1
0
: -47.0
dBm
(C)
0
1
1
: -48.5
dBm
(D)
1
0
0
: -50.0
dBm
(E)
1
0
1
: -51.5
dBm
(F)
1
1
0
: -53.0
dBm
(G)
1
1
1
: OFF
(H)
7
Impedance switching control in
pulse dialing
0: OFF
1: ON
8
Prompt beep when the memory
area for the activity report
becomes full
0: No
1: Yes
NOTE:
Selectors 1 through 6 are applicable to models equipped with built-in TADs.
NOTE:
Selectors 7 and 8 are applicable only to the European versions.
Selectors 1 through 6: Compression threshold level for voice signals inputted via the telephone line
in the built-in TAD operation
If voice signals inputted via the telephone line are below the level specified by these selectors, the
TAD interprets those received voice signals as no signal, compressing the recording time.
Selector 8: Prompt beep for activity report
This selector determines whether or not to beep if the memory area for the activity report becomes
full, for prompting you to print out the report. (Printing it out will clear the memory area.)