CHAPTER 4 HP-GL/2 - 12
7.
COMMANDS
7.1.
Initialize Commands
DF - Default set instruction
DF[;]
ï‚Ÿ
Returns the graphics mode to default conditions. The following are the default settings.
Function Equivalent
Instruction
Condition
Plot mode
PA;
Absolute plotting
Absolute direction
DI 1,0;
Horizontal
Line type
LT;
Solid line
Line pattern length
LT;
4% of distance from P1 to P2
Anchor corner
AC;
Lower left corner of picture frame
Line Attributes
LA;
Butt cap, mitered joints, miter limit = 5
User-Defined line type
UL;
All line types set to default
Window
IW;
Set at limits of printable area according to paper
size
Symbol mode
SM;
Off
Character Fill Mode
CF ;
Solid, Fill, no edging
Character set
SS;
Standard character set selected
Scalable or Bitmap
Fonts
SB 0;
Scalable font only
Character slant
SL 0;
0 degrees
Scaling SC
;
Off
Label terminator
DT chr$(3)
chr$(3), non-printing
Raster fill
RF;
Solid black
Fill type
FT;
solid fill
Transparency mode
TR1;
Transparency mode on
Screened vectors
SV;
No screening
Polygon mode
PM0PM2;
Polygon buffer empty
Standard font
SD;
Stick font
Alternate font
AD;
Stick font
Character size
transformation
SI; Off
Label origin
LO1;
Current pen location
Text path
DV;
Left to right with normal line feed
Extra space
ES;
No extra space
Transparent data
TD;
Normal printing mode
NOTE:
The location of the scaling points(P1, P2) remains constant.