7.2. Plot Area and Unit Setting Instructions; Plot Area and Unit Setting Instructions ; IP - Input scaling point - Page 170

Brother hl-1270n Command Reference Guide for Software Developers

Table of Contents

Technical Reference Guide
GLOSSARY
background image

 

CHAPTER 4 HP-GL/2 - 14 

7.2.

 

Plot Area and Unit Setting Instructions 

Instruction Function 
IP Scaling 

point 

IR 

Input relative scaling points 

SC Scale 
IW Input 

window 

RO 

Rotate coordinate system 

 

IP - Input scaling point   

IP [ P1

X

, P1

[,P2

X,

 P2

Y

]] [;]  

P1

X

 ; 

X

 coordinate of P1  P1

Y

 ; 

Y

 coordinate of P1 

P2

X

 ; 

X

 coordinate of P2  P2

Y

 ; 

Y

 coordinate of P2 

 

The coordinates used are absolute values in graphics units. 

 

Set the location of the scaling points(P1,P2). 

 

Coordinate values for P1X,P1Y, P2X and P2Y are given as integer numbers. 

 

You can set P1 and P2 to be anywhere that the range of allowable coordinates permits.    However,    only 
parts of resulting images that lie within the effective window will be printed. 

 

The default location of P1 is the lower left corner and P2 is the upper right corner of the PCL picture frame. 

 

Using this instruction without a parameter field initializes the scaling points(P1,P2) to the default location. 

 

P2X and P2Y may be omitted.    If P2X and P2Y are omitted, P2 is set automatically so as not to alter the 
distance between P1 and P2. 

 

If P2x and P2y are omitted P2 is set to be in the same position relative to P1 that it was before the command 
was invoked. 

 

The IP command remains in effect until another IP command,    an IR command or an IN command is used. 

 

IR - Input relative scaling points 

IR [ P1x, P1y [, P2x, P2y]][;]

 

P1x ; x-coordinate of P1  P1y ; y-coordinate of P1

 

P2x ; x-coordinate of P2  P2y ; y-coordinate of P2 

 

The coordinate values are percentages relative to the bottom left and top right hand corners of the picture 
frame. 

 

Coordinate values for P1x, P1y, P2x, and P2y are treated as clamped real numbers. 

 

Using this instruction without parameters sets the scaling points (P1, P2) to their initial positions, the bottom 
left and top right hand corners of the picture frame. 

 

If P2x and P2y are omitted P2 is set to be in the same position relative to P1 that it was before the command 
was invoked. 

 

You can set P1 and P2 to be anywhere that the range of allowable coordinates permits.    However,    only 
parts of resulting images that lie within the effective window will be printed. 

 

The IR command remains in effect until another IR command,    and IP command or an IN command is used. 

 

Detailed Information for Brother hl-1270n Command Reference Guide for Software Developers

Lists of information found in Brother hl-1270n Command Reference Guide for Software Developers - Page 170

  • 7.2.
  • 2.  If P2x and P2y are omitted P2 is set to be in the same position relative to P1 that it was before the command was invoked.

Related Documents for Brother hl-1270n Command Reference Guide for Software Developers