3.2. Plot Area and Unit Setting Instructions; Function Equivalent ; Instruction - Page 358

Brother hl-1270n Command Reference Guide for Software Developers

Table of Contents

Technical Reference Guide
GLOSSARY
background image

 

CHAPTER 9 HP-GL - 7 

 

Function Equivalent 

Instruction 

Condition 

Fill type 

FT; 

Bi-directional fill, type 1 

Fill distance 

FT; 

1% of distance from P1 to P2 

Fill slant 

FT; 

0 degrees 

Pen thickness 

PT; 

Set at 0.3 mm 

Pen condition 

PU; 

Pen up 

Rotation 

RO; 

Set at 0 degrees 

Scaling points 

IP; 

Initialized according to  
paper size 

 

3.2.

 

Plot Area and Unit Setting Instructions 

Instruction Function 
IP 

Scaling point  

SC Scale 
IW Input 

window 

RO 

Rotate coordinate system 

PG Page 

output 

 

IP - Input scaling point  

IP [ P1

X

, P1

[,P2

X,

 P2

Y

]] [;]  

P1

X

 ; 

X

 coordinate of P1    

P1

Y

 ; 

Y

 coordinate of P1 

P2

X

 ; 

X

 coordinate of P2    

P2

Y

 ; 

Y

 coordinate of P2 

 

 

The coordinate values used are absolute values in graphics units. 

 

Sets the location of the scaling points(P1, P2). 

 

Coordinate values for P1

X

, P

1Y

P2X

 and P2

Y

 are given as integer numbers. 

The IP instruction is ignored when the set coordinates are outside the print area. 

 

Using this instruction without a parameter field initializes the scaling points(P1, P2). 

 

P2X and P2Y may be omitted.  (If P2X and P2Y are omitted, P2 is set automatically so as not to alter the 
distance between P1 and P2). 

 

SC - Scale 

SC   Xmin,  Xmax, Ymin, Ymax 

Xmin ; X coordinate of P1  

 

Xmax ; X coordinate of P2 

Ymin ; Y coordinate of P1  

 

Ymax ; Y coordinate of P2 

 

 

Sets the scale for the coordinates the user wants to establish. 

 

Coordinate values for Xmin,  Xmax, Ymin and Ymax are given as real numbers.  

 

Using this instruction without a parameter field turns the scaling off. 

 

The technical terms user unit and graphics unit as used in this manual are defined as follows; 
  

User unit 

: the unit of the coordinates set by the SC instruction 

  

Graphics unit 

: the unit (1/1016 of an inch) of the coordinates not set by the SC instruction 

 
10 '*** SCEX *** 
20 LPRINT "IN; IP3000,2000,4500,3500;SP1;SC0,120,0,120;" 
30 FOR T=0 TO 2*3.1416+3.1416/20 STEP 3.1416/20 
40 X=COS(T)*100 
50 Y=SIN(T)*100 
60 LPRINT "PA";X;",";Y;";PD;" 
70 NEXT T 
80 LPRINT "PU;" 
90 END 
 

  <Sample 

61> 

Detailed Information for Brother hl-1270n Command Reference Guide for Software Developers

Lists of information found in Brother hl-1270n Command Reference Guide for Software Developers - Page 358

  • 3.2.
  • 3.1416+3.

Related Documents for Brother hl-1270n Command Reference Guide for Software Developers