8.5.15. Entity error codes; 8.5.16. Free space command; Entity error codes - Page 134

Brother HL-1470N Command Reference Guide for Software Developers

Table of Contents

Technical Reference Guide
GLOSSARY
background image

 

CHAPTER 2 PCL - 114 

Status location type 1 (selected at present) is an incorrect location for unbound font symbol sets and returns an 
error. 

Example responses in this section for "SYMBOLSETS=" do not indicate the complete list of symbol sets which 
are available internally, but only a partial list . The internal symbol sets depend on the printer and might differ 
according to the printer. 

 

8.5.15.

 

Entity error codes 

When an out-of-range value exists in the command value fields, or when the entity is not supported or does not 
exist, or the request is inadequate, the printer replies with one of four likely errors as follows: 

Invalid Entity 
Invalid Location 
None 
Internal Error 
ERROR=INVALID ENTITY 

When the identified entity type is not in the range or not supported, it returns an invalid entity error.  

PCL 
INFO ENTITY 
ERROR=INVALID ENTITY 
ERROR=INVALID LOCATION 

When the entity type is correct, but the location ( the type, the unit, or the combination) is not, or when the 
identified device is not installed, it returns an invalid location error.  

PCL 
INFO FONTS 
ERROR=INVALID LOCATION 
ERROR=NONE 

When the entity type and location are correct, but there are not any entities of the identified type in the location, 
or when the type is not correct for the identified entity, it generates the NONE error response.  

PCL 
INFO SYMBOLSETS 
ERROR=NONE 
ERROR=INTERNAL ERROR 

The status response for some requirements could be quite big. When status replies are requested, it returns an 
internal error if the printer runs out of memory as follows: 

PCL 
INFO SYMBOL SETS 
ERROR=INTERNAL ERROR 

 

8.5.16.

 

Free space command 

ESC*s1M (27)(42)(115)(48)(77) <1Bh><2Ah><73h><31h><4Dh> 

The amount of memory which is free for use is returned by this command. Two values are returned: the total 
amount of free memory and the largest block of free memory. 

When you send a value other than 1, an error ( "ERROR = INVALID UNIT" )is returned. 

The Free Space command is sent to check the free memory space and you can acknowledge whether the printer 
has enough memory for a job or not before you execute your job.  Also you can check the amount of memory 
which an entity or any other data has already used.  

Free memory space will  always be changing during different printing conditions. 

For example, when the printer receives print data,  it is stored in the printer memory and so the free space 
in the printer memory becomes smaller.  After the data is printed,  the printer memory becomes empty, so 
the free space becomes larger again. 

Certain action is needed when you decide there is not enough memory to hold the data to be downloaded.  

 

Detailed Information for Brother HL-1470N Command Reference Guide for Software Developers

Lists of information found in Brother HL-1470N Command Reference Guide for Software Developers - Page 134

  • 8.5.
  • 15. Entity error codes When an out-of-range value exists in the command value fields, or when the entity is not supported or does not exist, or the request is inadequate, the printer replies with one of four likely errors as follows: Invalid Entity Invalid Location None Internal Error ERROR=INVALID ENTITY When the identified entity type is not in the range or not supported, it returns an invalid entity error.
  • 8.5.
  • 16. Free space command ESC*s1M (27)(42)(115)(48)(77) &lt;1Bh&gt;&lt;2Ah&gt;&lt;73h&gt;&lt;31h&gt;&lt;4Dh&gt; The amount of memory which is free for use is returned by this command.

Related Documents for Brother HL-1470N Command Reference Guide for Software Developers