3.4 Data; 3.4.1 Save data; 3.4.2 Execute data- Page 512

Brother HL-2460 Command Reference Guide for Software Developers

Table of Contents

Technical Reference Guide
GLOSSARY
background image

 

APPENDIX B - FLASH/PCMCIA CARD COMMANDS - 8 

3.4

 

Data 

3.4.1

 

Save data   

Command 

ESC CR ! 12347F ID(2byte) size(4byte) data... 

Available Devices 

F, A, H 

Description 

This command saves data which is sent from the PC with the specified ID onto the device.  

If there is insufficient memory in the printer to store the data, a memory full error occurs. 

When the printer supports two or more storage devices, the command saves the data onto the device specified by 
the select storage device command.  When only one device is enabled, the command saves onto that device. 

Error 

HL-1660e/2060/2400C: 

34 MEMORY FULL  

 

 

43 CARD1 W ERROR 

 

 

43 CARD2 W ERROR 

 

 

HL-2400Ce/3400CN 

43 DEVICE1 W ERROR 

43 DEVICE2 W ERROR 

43 DEVICE3 W ERROR 

HL-2460/3260N/2600CN/3450CN/7050: 

43 CARD ERROR 

43 HDD ERROR 

HL-
1650/1670N/1850/1870N/5070N/5170DN/5270DN/5280DW/5380DN/6180DW/5470DW/5450DN/5440D/S7000DN: 

43 SERVICE E74 

HL-6050/6050D/6050DN/8050N/2700CN: 

43 CARD ERROR 

 
 

3.4.2

 

Execute data 

 

Command 

ESC CR ! 12349F ID(2byte) 

Available Devices 

F, A, H 

Description 

This command executes the specified ID data.  

When the printer supports two or more storage devices, the command saves the data onto the device specified by 
the select storage device command.  When only one device is enabled, the command saves onto that device. 

Error 

N/A 

Detailed Information for Brother HL-2460 Command Reference Guide for Software Developers

Lists of information found in Brother HL-2460 Command Reference Guide for Software Developers - Page 512

  • 3.4 Data 3.
  • 4.1 Save data Command ESC CR ! 12347F ID(2byte) size(4byte) data.
  • 3.4.

Related Documents for Brother HL-2460 Command Reference Guide for Software Developers