3.3. Bar Code Scaling (Width only); 3.4. Bar Code Human Readable Line On or Off; 3.5. Quiet Zone- Page 346

Brother HL-2600CN Command Reference Guide for Software Developers

Table of Contents

Technical Reference Guide
GLOSSARY
background image

CHAPTER 8 BAR CODE CONTROL - 7 

 Line Block Drawing & Box Drawing Shading 

"S"  1 = Black 
 

2 = Vertical stripes 

 

3 = Horizontal stripes 

 

4 = Cross hatch 

 

3.3.

 

Bar Code Scaling (Width only) 

n = "mnnn" or "Mnnn"    (nnn = 0 ~ 32767) 

This parameter specifies the bar code width scaling.    The unit of "nnn" is %.    The default value is m100 
(100%). 

 

3.4.

 

Bar Code Human Readable Line On or Off 

n = "r0" or "R0" 

Human readable line OFF 

n = "r1" or "R1" 

Human readable line ON 

 

Default: 

Human readable line ON when the following barcode types are selected. 

 

(1)  "T5" or "t5" 

 

(2)  "T6" or "t6" 

 

(3)  "T130" or "t130" 

 

(4)  "T131" or "t131" 

Default: 

Human readable line OFF 

  

All 

others 

This parameter specifies whether or not the printer prints the human readable line below the bar code.    Human 
readable characters are always printed with OCR-B font at 10 cpi pitch    and all the current character style 
enhancements are masked.    Note that the default setting is subject to the bar code mode selected by "t" or "T".     

 

3.5.

 

Quiet Zone 

n =    "onnn" or "Onnn" (nnn = 0 ~ 32767) 

Quiet Zone is the space on both side of the bar codes.    Its width can be specified using the units which are set 
by the "u" or "U" parameter.    ( For the description of "u" or "U" parameter,    see the next section.)    The 
default setting of Quiet Zone width is 1 inch. 

 

3.6.

 

Bar Code, Expanded Character Unit, Line Block Drawing & Box Drawing 
Units 

n = "u0" or "U0" 

Millimeters (default) 

n = "u1" or "U1" 

1/10" 

n = "u2" or "U2" 

1/100" 

n = "u3" or "U3" 

1/12" 

n = "u4" or "U4" 

1/120"   

n = "u5" or "U5" 

1/10 Millimeter 

n = "u6" or "U6" 

1/300" 

n = "u7" or "U7" 

1/720" 

This parameter specifies the measurement units of X-axis offset, Y-axis offset and bar code height.     

 

Detailed Information for Brother HL-2600CN Command Reference Guide for Software Developers

Lists of information found in Brother HL-2600CN Command Reference Guide for Software Developers - Page 346

  • 3.3.
  • 3.4.
  • 3.5.
  • 3.6.

Related Documents for Brother HL-2600CN Command Reference Guide for Software Developers