CHAPTER 5 MAINTENANCE
5-26
Note
If the condition of the Fuser Cleaner is poor, we recommend that you replace
the Fuser Cleaner at the same time as the Fusing Unit. The life counter for
the Fuser Cleaner will also need to be reset. Please refer to page 5-15 for
instructions.
Partially used Oil Bottles can be reused with a new Fusing Unit.
Please wait for 30 minutes after installing a new Fusing Unit to allow
the oil to circulate completely through to the Heat Roller.
11.
Press the Power button to turn on the printer.
12.
Press any of the Menu buttons (+, – , Set or Back) to take the printer Off
Line.
13.
Press + or – until “RESET MENU” appears.
14.
Press Set to proceed to the next menu level, and then press + or – until
“PARTS LIFE” appears.
15.
Press Set, and then press + until “FUSER UNIT” appears.
16.
Press Set, and then press Go. The printer is now in the READY state.
!
Caution, Warning
Please be careful when replacing the Fusing Unit. Do not put pressure on
the Fusing Unit; it should fit in easily. If it does not, make sure the Fusing
Unit connector is free to move.
Do not apply force! It could damage both the Fusing Unit and the printer.