3.13. Box Drawing; 3.14. Line Block Drawing; 3.15. Expanded Character Data Start- Page 349

Brother HL-7050N Command Reference Guide for Software Developers

Table of Contents

Technical Reference Guide
GLOSSARY
background image

CHAPTER 8 BAR CODE CONTROL - 10 

 

When Code 128 Set A, Set B, or Set C is selected with the parameter "t12" or "12," "t13" or "T13," or "t14" 
or "T14" respectively:     

 

Code sets A, B and C are individually selectable.    Set A encodes characters in the range Hex 00 to 5F.    Set 
B encodes characters in the range Hex 20 to 7F.    Set C encodes numeric pairs in the range 00 to 99.     

-  Switching is allowed between the code sets by sending %A, %B, or %C.     

-  FNC 1, 2, 3, and 4 are produced with %1, %2, %3, and %4.     

-  The SHIFT code, %S, allows temporary switching (for 1 character only) between    set A and set B and 

vice versa.   

-  To print the  "%" character,    it must be sent twice. 

When you put "?" on the end of the data, a check digit is automatically added. 

 

When ISBN (EAN) is selected with the parameter "t130" or "T130":     

 

The rules are the same as for    "t5" or "T5" 

 

When the ISBN (UPC-E) is selected with the parameter "t131" or "T131":     

The rules are the same as for "t6" or "T6" 

 

When EAN 128 set A, set B or set C is selected with the parameter "t132" or "T132," "t133" or "T133" or 
"t134" or "T134" respectively: Same rules apply as for "t12" or "T12," "t13" or "T13", or "t14" or "T14." 
 

3.13.

 

Box Drawing 

(except HL-
L5000D/L5580D/L5100DN/L5200DW/L6200DW/L6300DW/L6400DW/L8250CDN/L8350CDW/L9200CDW
/L9300CDW/L2370DN/L2371DN/L2372DN/2590DN/B2050DN/L2370DW/L2375DW/L2376DW/B2080DW/
L2385DW/L2386DW/2595DW/L3270CDW/L3230CDW/L3230CDN/L3210CW/3190CDW/3160CDW) 

ESC i ... E (or e) 

 

"E" or "e" is a terminator.     

 

3.14.

 

Line Block Drawing 

(except HL-
L5000D/L5580D/L5100DN/L5200DW/L6200DW/L6300DW/L6400DW/L8250CDN/L8350CDW/L9200CDW
/L9300CDW/L2370DN/L2371DN/L2372DN/2590DN/B2050DN/L2370DW/L2375DW/L2376DW/B2080DW/
L2385DW/L2386DW/2595DW/L3270CDW/L3230CDW/L3230CDN/L3210CW/3190CDW/3160CDW) 

ESC i 

...

 V (or v) 

 

"V" or "v" is a terminator.     

 

3.15.

 

Expanded Character Data Start 

(except HL-
L5000D/L5580D/L5100DN/L5200DW/L6200DW/L6300DW/L6400DW/L8250CDN/L8350CDW/L9200CDW
/L9300CDW/L2370DN/L2371DN/L2372DN/2590DN/B2050DN/L2370DW/L2375DW/L2376DW/B2080DW/
L2385DW/L2386DW/2595DW/L3270CDW/L3230CDW/L3230CDN/L3210CW/3190CDW/3160CDW) 

n = "l" or "L" 

 

Data that follows "l" or "L" is read in as expanded character data (or labeling data).    Expanded character data 
must end with the " \ " code (5CH), which also terminates this command.    To print the '\' character, you must 
input '\\'.   

Detailed Information for Brother HL-7050N Command Reference Guide for Software Developers

Lists of information found in Brother HL-7050N Command Reference Guide for Software Developers - Page 349

  • 99. - Switching is allowed between the code sets by sending %A, %B, or %C.
  • 4. - The SHIFT code, %S, allows temporary switching (for 1 character only) between set A and set B and vice versa.
  • 14." 3.
  • 13. Box Drawing (except HL- L5000D/L5580D/L5100DN/L5200DW/L6200DW/L6300DW/L6400DW/L8250CDN/L8350CDW/L9200CDW /L9300CDW/L2370DN/L2371DN/L2372DN/2590DN/B2050DN/L2370DW/L2375DW/L2376DW/B2080DW/ L2385DW/L2386DW/2595DW/L3270CDW/L3230CDW/L3230CDN/L3210CW/3190CDW/3160CDW) ESC i .
  • 3.14.
  • 3.15.

FAQ (Frequently Asked Questions) for Brother HL-7050N Command Reference Guide for Software Developers - Page 349

  • When you put "?

Related Documents for Brother HL-7050N Command Reference Guide for Software Developers