44
* Note:
・
Both 00H through 09H and 30H through 39H are recognized as the parameter
numbers 0 through 9.
・
Parameter types a and b are recognized, even if they are uppercase letters.
・
The parameter "parentheses removed" is available only when GS1-128
(UCC/EAN
-
128) is selected.
・
The parameter “ratio between thick and thin bars” is available only when t0, t1
or t9 is selected.
・
If there is no type command or if an invalid type command has been specified,
Code 39 is specified.
・
The number of characters that can be entered for each bar code protocol is
listed below.
t0:
1
to 50 characters (not including “*” on both sides)
t1:
1 to 64 characters
t5:
7 characters (EAN-8), 12 characters (EAN-13), 11 characters
(UPC-A)
t6: 6
characters
t9:
3 to 64 characters (with “A”, “B”, “C” or “D” at the beginning and
end)
ta:
1 to 64 characters
tb:
1 to 64 characters
tc:
3 to 15 characters (begins with “01”) (except with RSS
Expanded)
1 to 64 numbers or 1 to 40 letters* (for RSS Expanded)
* ISO646 characters can be printed.
(numbers, letters, spaces, !, ”, %, &, ’, (, ), *, +, ,, -, ., /, :, ;, <,
=, >, ? and _)
②
B or b:
Beginning of bar code data
③
[Bar code data]: Data for the bar code
? (generate check digit)
Generates a check digit when “?” is in the bar code data
The position of “?” is irrelevant as long as it is within the bar code data.
With CODE128 and GS1-128 (UCC/EAN-128), no check digit is
generated.