Auto setting (default value); The default is “50”.- Page 52

Brother PT-9800PCN ESC/ P Command Reference

Table of Contents

Control command details
background image

 52 

* 0 and 1 to 4 with Micro PDF417

 

7. Symbol size in Y direction 
[1-byte decimal]   0 
[1-byte decimal]      3 to 90 

* 0 and 4 to 44 with MicroPDF417

 

 

Auto setting   (default value)

 

Manual setting

 

 

8. Aspect 

value 

[2-byte decimal]      1 to 1000 

 

 
Enter the aspect value. Actually, this is between 0.01 and 
10.0. However, since a decimal point cannot be entered, a 
value multiplied by 100 is entered. 

The default is “50”.

 (The actual value is 0.5.)

 

 

* Note: 

The aspect value setting is ignored if the symbol size in the X direction or the symbol size 

in the Y direction is entered manually. 

Depending on the conditions, the bar code may not be generated or a bar code that 
cannot be scanned may be generated if the symbol size in the X direction or the symbol 

size in the Y direction is entered manually. 

When a large cell size is specified together with a high error correction capacity, printing 
may not be possible because the print buffer has become full. 

[With symbol type Micro PDF417] 

Since the error correction capacity is automatically determined from the symbol size in 
the X direction, the settings for “Error correction capacity–type” and “Error correction 

capacity–value” are ignored. 

The aspect value setting is ignored. 

The following table shows the values available for the symbol size in the Y direction 

according to the symbol size in the X direction. If an invalid setting is specified for the 

symbol size in the Y direction, the default setting is specified. 

 

Symbol size in X 

direction 

Symbol size in Y direction 

AUTO

 

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

1

 

AUTO

 

11

14

17

20

24

28

 

 

 

 

 

2

 

AUTO

 

8

 

11

14

17

20

23

26

 

 

 

 

 

3

 

AUTO

 

6

 

8

 

10

12

15

20

26

 

32

 

38

 

44

 

4

 

AUTO

 

4

 

6

 

8

 

10

12

15

20

 

26

 

32

 

38

44

 

 

 Bar code data 

The number of bar code data characters that can be entered is listed below. 

1850 alphanumeric characters, 2710 numerals, 1108 bytes of binary data 

 

* Note: 

The number of characters that can be entered (listed above) is for when the error correction 

Detailed Information for Brother PT-9800PCN ESC/ P Command Reference

Lists of information found in Brother PT-9800PCN ESC/ P Command Reference - Page 52

  • 7. Symbol size in Y direction [1-byte decimal] 0 [1-byte decimal] 3 to 90 * 0 and 4 to 44 with MicroPDF417 Auto setting (default value) Manual setting 8.
  • 5.) * Note: ・ The aspect value setting is ignored if the symbol size in the X direction or the symbol size in the Y direction is entered manually.