Name; Raster graphics transfer; Syntax- Page 24

Brother QL-700 Raster Command Reference

Table of Contents

-
1
2
3
4
5
6
7
6
6
6
1
1
2
1
1
3
2
1
4
3
1
5
4
1
6
5
1
7
6
1
8
7
1
9
8
1
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
8
0
1
2
3
4
5
Word のしおり
background image

 

 

Name 

Raster graphics transfer 

Syntax 

g + {s} + {n} + {d1} + ... + {dn} 

67 H + {s} + {n} + {d1} + ... + {dn} 

Description 

{s} The definition of raster information s is as follows. 

s 0x0:  Data transmission 

    0x1

0xFE: Not 

used 

    0xFF: 

Indicates that data transmission should be stopped. 

{n} Transfers the specified number of bytes (n) of data.

 

(However, this changes if the 

data is compressed using the serial interface.) 

n=90 (QL-500/550/560/570/580N/650TD/700) 

n=162 (QL-1050/1060N) 

{d1-dn} Print data. 

 

Name

 

Zero raster graphics 

Syntax

 

Z  

5A H

   

Description

 

Raster line is filled in zero data. (Compression mode) 

 

Name 

Print command 

Syntax 

FF 

0C H 

Description 

Used as a print command, except for the last label when multiple labels are printed. 

 

Name 

Print command with feeding 

Syntax 

Control-Z 

1A H 

Description 

Used as a print command for the last label when multiple labels are printed. 

 

 

 

Name 

Baud rate setting (QL-580N/650TD/1050/1060N) 

Syntax 

ESC + i + B + {n1} + {n2} 

1B H + 69 H + 42H + {n1} + {n2} 

Description 

This changes the communications baud rate for the main unit. The factory setting is 

115200 bps 

Definition of {n1} and {n2} 

Setting = n1 + n2 * 256 

Setting:    96=9600 bps, 576=57600 bps, 1152=115200 bps 

Brother QL-500/550/560/570/580N/650TD/700/1050/1060N Command Reference 

 