Name
Raster graphics transfer
Syntax
g + {s} + {n} + {d1} + ... + {dn}
67 H + {s} + {n} + {d1} + ... + {dn}
Description
{s} The definition of raster information s is as follows.
s 0x0: Data transmission
0x1
~
0xFE: Not
used
0xFF:
Indicates that data transmission should be stopped.
{n} Transfers the specified number of bytes (n) of data.
(However, this changes if the
data is compressed using the serial interface.)
n=90 (QL-500/550/560/570/580N/650TD/700)
n=162 (QL-1050/1060N)
{d1-dn} Print data.
Name
Zero raster graphics
Syntax
Z
5A H
Description
Raster line is filled in zero data. (Compression mode)
Name
Print command
Syntax
FF
0C H
Description
Used as a print command, except for the last label when multiple labels are printed.
Name
Print command with feeding
Syntax
Control-Z
1A H
Description
Used as a print command for the last label when multiple labels are printed.
Name
Baud rate setting (QL-580N/650TD/1050/1060N)
Syntax
ESC + i + B + {n1} + {n2}
1B H + 69 H + 42H + {n1} + {n2}
Description
This changes the communications baud rate for the main unit. The factory setting is
115200 bps
Definition of {n1} and {n2}
Setting = n1 + n2 * 256
Setting: 96=9600 bps, 576=57600 bps, 1152=115200 bps
Brother QL-500/550/560/570/580N/650TD/700/1050/1060N Command Reference