Advanced Thermal Control

In this section, you can tailor the fan speed to specific applications. You have the choice of the following modes:

t /PSNBM

t &BSMZ

t 'VMM4QFFE

The fan mode can be changed using the front panel buttons at start-up or in the software. The default mode is normal and 
should work fine for most applications. Early mode turns the fan on sooner at a “lower” temperature, and Full-speed mode 
turns the fan on full-speed full-time. Full-speed mode is not recommended for “dirty” environments.

Advanced Monitoring

This feature allows you to have software visibility of both the Power Supply Temperature and AC Line voltage. AC Line 
voltage is “derived” from the amplifier rail voltage and is an approximation of the AC line voltage. This allows you to monitor 
the health of your amplifiers and provides for troubleshooting.

Front Panel Lock-Out

To disable or lock the buttons from the front panel, hold the Prev and Next at the same time until the screen says “locked”. 
The rotary knobs (attenuators) will still operate. To unlock, hold Prev and Next until the screen says “unlocked”.