Separator Hose); Checking Lift Cylinder Hose; Checking Radiator Hose and Hose Clamp- Page 66

Kubota L3560 Owners Manual

2014 Dodge Charger SRT Owner Manual

Table of Contents

L3560,L4060,L4760,L5060,L5460,L6060
9 ELECTRICAL SYSTEM
background image

GENERAL

L3560, L4060, L4760, L5060, L5460, L6060, WSM

G-37

Checking Radiator Hose and Hose Clamp

Check  to  see  if  radiator  hoses  are  properly  fixed  every  200

hours of operation or six months, whichever comes first.

1. If hose clamps are loose or water leaks, tighten bands securely.

2. Replace  hoses  and  tighten  hose  clamps  securely,  if  radiator

hoses are swollen, hardened or cracked.

Replace  hoses  and  hose  clamps  every  2  years  or  earlier  if

checked  and  found  that  hoses  are  swollen,  hardened  or

cracked.

Precaution at Overheating

Take the following actions in the event the coolant temperature

be  nearly  or  more  than  the  boiling  point,  what  is  called

"Overheating"

.

1. Stop the machine operation in a safe place and keep the engine

unloaded idling.

2. Don't stop the engine suddenly, but stop it after about 5 minutes

of unloaded idling.

3. Keep  yourself  well  away  from  the  machine  for  further  10

minutes or while the steam blown out.

4. Checking that there gets no danger such as burn, get rid of the

causes  of  overheating  according  to  the  manual,  see

"Troubleshooting" section, and then, start again the engine.

9Y1210824GEG0048US0

Checking Oil Cooler Line (HST)

1. Check to see that all lines and hose clamps are tight and not

damaged.

2. If hoses and clamps are found worn or damaged, replace repair

them at once.

9Y1210824GEG0046US0

Checking PCV (Positive Crankcase Ventilation) Valve Hose (Oil
Separator Hose)

• Check the hoses. (See page 1-S17.)

9Y1210824GEG0135US0

Checking Lift Cylinder Hose

1. Check the lift cylinder hose. (See page 8-S21.)

9Y1210824GEG0136US0

(1) Radiator Hose

(2) Clamp

(1) Oil Cooler

(2) HST Oil Line

KiSC issued 03, 2016 A

Detailed Information for Kubota L3560 Owners Manual

Lists of information found in Kubota L3560 Owners Manual - Page 66

  • 1. If hose clamps are loose or water leaks, tighten bands securely.
  • 2. Replace hoses and tighten hose clamps securely, if radiator hoses are swollen, hardened or cracked.
  • 1. Stop the machine operation in a safe place and keep the engine unloaded idling.
  • 2. Don't stop the engine suddenly, but stop it after about 5 minutes of unloaded idling.
  • 3. Keep yourself well away from the machine for further 10 minutes or while the steam blown out.
  • 4. Checking that there gets no danger such as burn, get rid of the causes of overheating according to the manual, see "Troubleshooting" section, and then, start again the engine.
  • 1. Check to see that all lines and hose clamps are tight and not damaged.
  • 2. If hoses and clamps are found worn or damaged, replace repair them at once.
  • 17.) 9Y1210824GEG0135US0 Checking Lift Cylinder Hose 1.
  • Check the hoses.