4 Operation
4.3 Navigating the LCD Control Screen
4.3.1 Functions, Controls and Screens
The LCD Control Screen and its controls let you view and set up
various parameters in the DBC Network Bridge. Settings made on
the LCD screen are duplicated in IQwic software, and vice-versa.
(DSP parameters cannot be adjusted with the LCD Control
Screen. That is done in IQwic.)
Figure 4.3 LCD Control Screen and Its Controls.
Left-to-right: Menu/Select Button, Prev Button,
Next Button, LCD Control Screen
Figure 4.3 shows the LCD Control Screen and its controls. Its
functions are described below.
The LCD Control Screen shows
:
32 Preset numbers
32 Scene numbers
Analog or digital audio input selections
IQ Address / IP Address/ Subnet Mask/MAC Address
Firmware Info
Errors
On power-up, the LCD Control Screen displays the Crown logo
and DBC logo. The screen defaults to the Preset display.
Scene Screen
is used to select Scenes.
Preset Screen
is used to select Presets.
Address Screen
is used to read addresses and subnet mask.
Input Board Menu
is used to select input signals.
Getting around in the Menu is intuitive. Here are the basic opera-
tions:
• Hold the
Menu/Select
button to cycle through the Preset
screen, Scene screen, Address screen, Input Board Menu, Firm-
ware Info screen, and back to the Preset screen.
• Press
Next
to go to a higher-numbered Preset, Scene, or
Input. Presets and Scenes loop around from 1 to 32.
• Press
Prev
to go to a lower-numbered Preset, Scene, or Input.
Presets and Scenes loop around from 32 back to 1.
• Press
Menu/Select
within 2 seconds after pressing
Next
or
Prev
to make a selection.
Preset 01 Active
PRESET 1
Scene 01 No Data
SCENE 1
IQ: 001
IP: 192.168.001.001
Sub:255.255.248.000
MAC:00-60-2B-02-8F-C0
INPUT BOARD MENU
Digital/Surround
Analog/Surround
Analog Auxiliary
Firmware Info Screen
displays the version of the
Control firmware and SHARC firmware.
FIRMWARE INFO
Control: 1.110
SHARC: 2.100
Once the
Menu/Select
button is released, the
Next
and
Prev
arrow buttons are used to adjust the parameter. On releasing the
Menu/Select
button, you have two seconds to press the
Next
or
Prev
button before the display changes back to default. When
the parameter is adjusted to the desired value, press the
Menu/
Select
button to store the setting.
Internal errors are automatically displayed on the LCD Control
Screen. If an error is displayed, call Tech Support at Crown and
provide them the error number.