DBC Network Bridge
Operation Manual
page 37
4.7.10 Presets
Click on the
Unit Presets
tab to open the
Presets
window (Figure 4.16).
The DBC Network Bridge has the ability to reconfigure itself with a single command. Thirty-two
'Presets' can be stored and recalled via a variety of means including the front panel, a Control Port
Input, or a scheduled 'Event'.
Preset 32 is the standard cinema setup
, which works in most
cases. Preset 32 is explained under number 6 below.
1. Store
For a Preset to be stored, all of the individual controls needs to be set up using IQwic while on-
line to the DBC Network Bridge, then press the 'Store' button and a select a Preset.
To ensure that settings are not inadvertently lost due to selecting a Preset instead of storing a Pre-
set, the “Prompt to recall or store” checkbox allows a query window to display whenever a Preset
button is pressed in order to ensure the intent of the user.
2. Label
Each Preset has a 32 character user-definable label.
3. Preset Segue
This enables smooth level transitions between Presets. When a Preset is selected, all of the fader
settings are changed at a rate that is determined by the ‘Preset Segue Settings’ box. The rate of
change can be either a 'Fixed Time' that is selectable from 0 second to 255 seconds or a 'Fixed
Rate' that goes from 0.5 dB/sec to 40 dB/sec.
4. Verify Recall or Store
When you click on a Preset number, this window appears so that you can recall the selected Pre-
set, store it, or cancel.
5. Preset Options Notice
Right-click on preset numbers to open more options: Load or save Presets to file, cut or copy Pre-
sets to clip area, and Edit Presets. Selecting
Edit Presets
opens the
Preset Editor
window
described on page 38.
6. Standard Cinema Preset Button (Preset 32)
Pressing this button recalls the preset for a standard cinema setup: a read-only preset that cannot
be edited by the user. If you want to create a preset based on Preset 32 but with changes, save it to
another Preset. The Standard Cinema preset contains the following settings in the DBC Network
Bridge:
•
The input is set to analog; the outputs are set to –20 dB.
•
The Monitor is set to Ch1 at 0 dB.
•
The CobraNet output for L, R, C, SW is set to TxA on Bundle 100 at 24 -bit.
•
The CobraNet output for SL, SR, BSL, BSR is set to TxB on Bundle 200 at 24-bit.
•
The CobraNet input for all eight input channels set to TxA on Bundle 300.
4 Operation
Figure 4.16 Presets Window
1
2
3
4
5
6