Operation Manual; 6 Troubleshooting ; DBC Network Bridge - Page 71

Crown 137769-3 User Manual

2014 Dodge Charger SRT Owner Manual
background image

DBC Network Bridge 

Operation Manual

page 71

CONDITION: Computer does not communicate with 
the network devices.

POSSIBLE REASON:

•     Incorrect wiring. See Section 1.1.1 on wiring.
•     IP Addressing is not done correctly. See Section 1.2 on addressing 
rules.

CONDITION: LINK/ACTIVITY LED does not light, 
even though the network cable is plugged in.

POSSIBLE REASON:

•      Ethernet link is broken.
•      Network connection is 10 Megabits instead of 100 Megabits.

CONDITION: Both LEDs flashing.

POSSIBLE REASON:

Fatal error. 

6 Troubleshooting 

CONDITION: IN USE/CONDUCTOR LED does not 
light, even though the network cable is plugged in.

POSSIBLE REASON:

•      Ethernet link is broken.
•      Network connection is 10 Megabits instead of 100 Megabits.

IN U

S

E/

COND

LINK/
ACT

IN U

S

E/

COND

LINK/
ACT

IN U

S

E/

COND

LINK/
ACT

On the connector are two LEDs. The left LED (IN USE/CONDUCTOR) lights yellow when the port is in use and will 
blink if the device is also the conductor (the CobraNet timing-master device). The right LED (LINK/ACTIVITY) lights 
green when link is established and blinks when network activity is detected. Both LEDs flash yellow in unison to 
report a fatal error.

Detailed Information for Crown 137769-3 User Manual

Lists of information found in Crown 137769-3 User Manual - Page 71

  • 1.1.
  • 1.2 on addressing rules.
  • Incorrect wiring.
  • IP Addressing is not done correctly.
  • Ethernet link is broken.
  • Network connection is 10 Megabits instead of 100 Megabits.
  • Fatal error.