DBC Network Bridge
Operation Manual
page 71
CONDITION: Computer does not communicate with
the network devices.
POSSIBLE REASON:
• Incorrect wiring. See Section 1.1.1 on wiring.
• IP Addressing is not done correctly. See Section 1.2 on addressing
rules.
CONDITION: LINK/ACTIVITY LED does not light,
even though the network cable is plugged in.
POSSIBLE REASON:
• Ethernet link is broken.
• Network connection is 10 Megabits instead of 100 Megabits.
CONDITION: Both LEDs flashing.
POSSIBLE REASON:
•
Fatal error.
6 Troubleshooting
CONDITION: IN USE/CONDUCTOR LED does not
light, even though the network cable is plugged in.
POSSIBLE REASON:
• Ethernet link is broken.
• Network connection is 10 Megabits instead of 100 Megabits.
IN U
S
E/
COND
LINK/
ACT
IN U
S
E/
COND
LINK/
ACT
IN U
S
E/
COND
LINK/
ACT
On the connector are two LEDs. The left LED (IN USE/CONDUCTOR) lights yellow when the port is in use and will
blink if the device is also the conductor (the CobraNet timing-master device). The right LED (LINK/ACTIVITY) lights
green when link is established and blinks when network activity is detected. Both LEDs flash yellow in unison to
report a fatal error.