Operation Manual; Thermal Dispation; AC Power Draw and Thermal Disspation:- Page 19

Crown CT 875 User Manual

2014 Dodge Charger SRT Owner Manual
background image

CT Power Amplifiers

page 19

CT Power Amplifiers

Operation Manual

17 AC Power Draw and Thermal Dissipation

ComTech DriveCore 875

Load

Watts in 

Watts 

out

120VAC

Watts

Dissipated

Watts in

Watts out

240VAC

Watts

Dissipated

Thermal Dispation

Line

Current

Watts Out 

Per 1A Line 

Current

Line 

Current

Watts Out 

Per 1A Line 

Current

btu/hr

kcal/hr

Idle (Deep Sleep)

-

0.9

<0.1

1.00

0.90

<0.1

1

3.41

0.86

Idle (Auto Standby)

-

17

0.40

17.00

15.50

0.25

15.8

57.97

14.60

Idle (Awake)

-

23

0.50

23.00

21.00

0.32

25

85.25

21.48

Idle (Green Power)

-

14.5

0.40

-

14

0.30

-

-

-

1/8th Power Pink 

Noise

8

117

75

2.40

31

42

114

75

1.32

57

39

143.22

36.08

6

121

75

2.50

30

46

117

75

1.40

54

42

156.86

39.51

4

126

75

2.60

29

51

122

75

1.60

47

47

173.91

43.81

1/3rd Power Pink 

Noise

8

277

200

4.66

43

77

270

200

2.85

70

70

262.57

66.14

6

284

200

4.90

41

84

275

200

2.90

69

75

286.44

72.16

4

292

200

5.30

38

92

283

200

3.00

67

83

313.72

79.03

1/8th Power Sine

8

115

75

2.11

35

40

113

75

1.27

59

38

136.40

34.36

6

116

75

2.14

35

41

114

75

1.28

58

39

139.81

35.22

4

119

75

2.20

34

44

118

75

1.32

57

43

150.04

37.80

1/3rd Power Sine

8

269

200

4.60

43

69

266

200

2.77

72

66

236.31

59.53

6

273

200

4.66

43

73

269

200

2.80

71

69

248.93

62.71

4

283

200

4.82

42

84

279

200

2.90

69

79

285.08

71.81

AC Power Draw and Thermal Disspation:

Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.                                                             

Typical line impedance used.                                                                                                               

Measurements made with 120/240 VAC mains.                                                                                                     

Data based on all channels driven at 8 Ohms.

Detailed Information for Crown CT 875 User Manual

Lists of information found in Crown CT 875 User Manual - Page 19

  • 1.00 0.
  • 3.41 0.
  • 17.00 15.
  • 15.8 57.
  • 14.60 Idle (Awake) - 23 0.
  • 23.00 21.
  • 85.25 21.
  • 14.5 0.
  • 2.40 31 42 114 75 1.
  • 43.22 36.
  • 2.50 30 46 117 75 1.
  • 56.86 39.
  • 2.60 29 51 122 75 1.
  • 73.91 43.
  • 4.66 43 77 270 200 2.
  • 62.57 66.
  • 4.90 41 84 275 200 2.
  • 86.44 72.
  • 5.30 38 92 283 200 3.
  • 13.72 79.
  • 2.11 35 40 113 75 1.
  • 36.40 34.
  • 2.14 35 41 114 75 1.
  • 39.81 35.
  • 2.20 34 44 118 75 1.
  • 37.80 1/3rd Power Sine 8 269 200 4.
  • 2.77 72 66 236.
  • 59.53 6 273 200 4.
  • 2.80 71 69 248.
  • 62.71 4 283 200 4.
  • 2.90 69 79 285.
  • 71.81 AC Power Draw and Thermal Disspation: Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.

Related Documents for Crown CT 875 User Manual