P O R TA B L E P A
Protection
Provides extensive protection and diagnostic
capabilities, including output current limiting,
DC protection, circuit breaker, and thermal
protection.
Construction
Ventilation:
Flow-through ventilation from
front to back.
Cooling:
Internal heat sinks with forced-air
cooling for rapid, uniform heat dissipation.
Air Volume Requirements
(per minute per unit):
80.15 ft³ (2.27 m³).
Dimensions:
EIA Standard 19-inch (48.3-cm)
rack mount width (EIA RS-310-B), 5.25-inch
(13.3-cm) height and 15.5-inch (39.5-cm)
depth.
Weight
Net Weight:
62.0 lb (27.7 kg)
Shipping Weight:
74.0 lb (33.6 kg)
Regulatory Certifications
Other Applications
SPECIFICATIONS
Performance
Sensitivity (
for full rated power at 4 ohms)
:
1.25 Vrms.
Frequency Response
(at 1 watt, 22 Hz to 20 kHz): +0 dB, –1 dB.
Signal-to-Noise Ratio
(20 Hz to 20 kHz, inputs terminated):
A-weighted, below rated power: > 100 dB.
No weighting, below rated power: > 95 dB.
Total Harmonic Distortion (THD):
< 0.5%.
Intermodulation Distortion (IMD):
(60 Hz and 7 kHz at 4:1) from full rated
output to –40 dB: < 0.3%.
Damping Factor (8 ohm) 10 Hz to 400 Hz:
>200.
Crosstalk
(below rated power)
:
at 1 kHz: –75 dB.
at 20 kHz: –59 dB.
Input Impedance
(nominal)
:
20 kilohms balanced, 10 kilohms unbalanced.
Load Impedance:
2 to 8 ohms per channel in
Stereo, 4 to 8 ohms in Bridge Mono.
AC Line Voltage and Frequency
Configurations Available (±10%):
120 VAC
60 Hz, 100 VAC 50/60 Hz, 220 VAC 50 Hz,
and 230-240 VAC.
Controls
Level:
Two front-panel rotary level controls,
one for each channel.
Power:
Front-panel switch; on when in the
IN position.
Circuit Breaker:
Back-panel breaker provides
overload protection.
Mode Switch:
Back-panel switch selects Dual
or Bridge-Mono mode.
Indicators
Signal Presence Indicators:
Two green LEDs,
one for each channel, illuminate when the
channel’s input signal exceeds –40 dBu.
Clip Indicators:
Two red LEDs, one for each
channel, illuminate when the channel’s output
is being overdriven.
Power Indicator:
Blue LED indicates
amplifier has been turned on and AC power
is available.
Fault Indicator:
Two red LEDs, one for each
channel, illuminate when amplifier is in
protect mode. Also illuminates briefly during
normal power-up when amplifier is first
switched on.
Input/Output
Input Connectors:
One per channel;
back-panel three-pin female XLR input
connectors.
Output Connectors:
Two 4-Pole Speakon
®
Output Connectors accept 2-pole or 4-pole
Speakon
®
connectors. The top Speakon
connector is wired for both channels so it can
be used for bridge-mono wiring or for stereo
wiring of two speakers to a single Speakon
connector.
One pair of back-panel binding posts per
channel; accepts banana plugs or bare wire.
(European models do not accept banana
plugs.)
T
he XLS 5000 power amplifier from Crown represents a new
era in affordable, quality power amplification. It incorporates
the best of tried-and-true design principles and innovative
features, all in a rugged, light-weight 3U chassis.
3/08 139436-3B