Operation Manual; Control Port Window: Digital Outputs Section; Control Port - Page 52

Crown 137769-3 User Manual

2014 Dodge Charger SRT Owner Manual
background image

Operation Manual

DBC Network Bridge

page 52

Control Port Window: Digital Outputs Section

In the 

Control Port 

window, find the 

Digital Outputs

 section (Figure 5.10).

There are eight digital outputs. Each output may be controlled manually, config-
ured to indicate the state of a binary object or, configured to indicate whether a 
particular Preset is loaded. There is one indicator and five controls for each out-
put:

1. Output State (Pin State Indicator)

Indicates the logical ‘Pin-High’ or ‘Pin-Low’ status of the actual hardware output.

2. Manual

Directly controls the output state of the corresponding pin when in Manual 
mode.

3. Polarity

Changes the polarity of the digital output regardless of the pin control mode.

4. Reflect Manual

This causes the output to directly reflect the state of its Manual control.

5. Reflect Object

This causes the output to reflect the state of the selected binary object within the 
DBC Network Bridge. Only a single object may be specified.

6. Reflect Preset

This causes the output to reflect whether the chosen Preset number is loaded 
within the DBC Network Bridge.

When the Control Port digital outputs are turned 'on', +10VDC at 10 mA is sup-
plied across the output to ground. A total of 1 amp of current is available.

There are many possible uses for the Control Port outputs. For example, they 
can be used to turn on auxiliary cooling fans. To do this the output signal might 
be used to close a relay (Figure 5.11). The relay would then turn the fans on or 
off.

By monitoring the operating condition of amplifiers (with the IQwic software), 
the need for additional cooling would be apparent. The software could then be 
used to turn on the appropriate Control Port input.

Another use for the Control Port outputs might be to light an LED on an annun-
ciator panel to indicate Preset status, input channel mute, or any other on/off 
type function (Figure 5.12).

5 Advanced Operation

Figure 5.10 Digital Outputs Section of 

the Control Port Window

Figure 5.11   

A Sample Control-Port Output Circuit

Figure 5.12 

 A Sample Control-Port 

Output LED Circuit

Detailed Information for Crown 137769-3 User Manual

Lists of information found in Crown 137769-3 User Manual - Page 52

  • 5.10).
  • 1. Output State (Pin State Indicator) Indicates the logical ‘Pin-High’ or ‘Pin-Low’ status of the actual hardware output.
  • 2. Manual Directly controls the output state of the corresponding pin when in Manual mode.
  • 3. Polarity Changes the polarity of the digital output regardless of the pin control mode.
  • 4. Reflect Manual This causes the output to directly reflect the state of its Manual control.
  • 5. Reflect Object This causes the output to reflect the state of the selected binary object within the DBC Network Bridge.
  • 6. Reflect Preset This causes the output to reflect whether the chosen Preset number is loaded within the DBC Network Bridge.
  • 5.11).
  • 5.12).
  • 5.10 Digital Outputs Section of the Control Port Window Figure 5.