Function ; Equivalent ; Instruction - Page 332

Brother 1660e User Manual

2014 Dodge Charger SRT Owner Manual
background image

2001/10/02 

CHAPTER 9 HP-GL - 7 

 

Function 

Equivalent 
Instruction 

Condition 

Fill type 

FT; 

Bi-directional fill, type 1 

Fill distance 

FT; 

1% of distance from P1 to P2 

Fill slant 

FT; 

0 degrees 

Pen thickness 

PT; 

Set at 0.3 mm 

Pen condition 

PU; 

Pen up 

Rotation 

RO; 

Set at 0 degrees 

Scaling points 

IP; 

Initialized according to  
paper size 

 

3.2. 

Plot Area and Unit Setting Instructions 

Instruction 

Function 

IP 

Scaling point  

SC 

Scale 

IW 

Input window 

RO 

Rotate coordinate system 

PG 

Page output 

 

IP - Input scaling point  

IP [ P1

X

, P1

[,P2

X,

 P2

Y

]] [;]  

P1

X

 ; 

X

 coordinate of P1  

 

P1

Y

 ; 

Y

 coordinate of P1 

P2

X

 ; 

X

 coordinate of P2  

 

P2

Y

 ; 

Y

 coordinate of P2 

 

• 

The coordinate values used are absolute values in graphics units. 

• 

Sets the location of the scaling points(P1, P2). 

• 

Coordinate values for P1

X

, P

1Y

P2X

 and P2

Y

 are given as integer numbers. 

The IP instruction is ignored when the set coordinates are outside the print area. 

• 

Using this instruction without a parameter field initializes the scaling points(P1, P2). 

• 

P2

X

 and P2

Y

 may be omitted.  (If P2

X

 and P2

Y

 are omitted, P2 is set automatically so as not to alter the distance 

between P1 and P2). 

 

SC - Scale 

SC   Xmin,  Xmax, Ymin, Ymax 

Xmin ; X coordinate of P1    

Xmax ; X coordinate of P2 

Ymin ; Y coordinate of P1    

Ymax ; Y coordinate of P2 

 

• 

Sets the scale for the coordinates the user wants to establish. 

• 

Coordinate values for Xmin,  Xmax, Ymin and Ymax are given as real numbers.  

• 

Using this instruction without a parameter field turns the scaling off. 

• 

The technical terms user unit and graphics unit as used in this manual are defined as follows; 
 

 

User unit 

: the unit of the coordinates set by the SC instru ction 

 

 

Graphics unit 

: the unit (1/1016 of an inch) of the coordinates not set by the SC 

instruction 

 

10 '*** SCEX *** 

20 LPRINT "IN; IP3000,2000,4500,3500;SP1;SC0,120,0,120;" 

30 FOR T=0 TO 2*3.1416+3.1416/20 STEP 3.1416/20 

40 X=COS(T)*100 

50 Y=SIN(T)*100 

60 LPRINT "PA";X;",";Y;";PD;" 

70 NEXT T 

80 LPRINT "PU;" 

90 END 

 

 

 

<Sample 61> 

Detailed Information for Brother 1660e User Manual

Lists of information found in Brother 1660e User Manual - Page 332

  • 3.2.
  • 3.1416+3.
  • The coordinate values used are absolute values in graphics units.
  • Sets the location of the scaling points(P1, P2).
  • Coordinate values for P1 X , P 1Y , P2X and P2 Y are given as integer numbers.
  • Using this instruction without a parameter field initializes the scaling points(P1, P2).
  • P2 X and P2 Y may be omitted.
  • Sets the scale for the coordinates the user wants to establish.
  • Coordinate values for Xmin, Xmax, Ymin and Ymax are given as real numbers.
  • Using this instruction without a parameter field turns the scaling off.
  • The technical terms user unit and graphics unit as used in this manual are defined as follows; User unit : the unit of the coordinates set by the SC instru ction Graphics unit : the unit (1/1016 of an inch) of the coordinates not set by the SC instruction 10 '*** SCEX *** 20 LPRINT "IN; IP3000,2000,4500,3500;SP1;SC0,120,0,120;" 30 FOR T=0 TO 2*3.

Related Documents for Brother 1660e User Manual