Confidential
9-31
I-4
All black
User Check
(1) Clean the corona wire of the drum unit.
(2) The drum unit may be damaged. Install a new drum unit.
Possible cause
Step
Check
Result
Remedy
Ground
contacts
1
Is the corona wire dirty?
Yes
Clean the corona wire
with the wire cleaner.
2
Is the corona wire broken?
Yes
Replace the drum unit.
Corona failure
3
Are the charge electrodes
between the printer body
and the drum unit dirty?
Yes
Clean both electrodes.
Harness
connection
4
Is the laser unit connected
to the main PCB correctly?
No
Connect the harness
between the laser unit
and the main PCB
correctly.
High-voltage
power supply
PCB failure
5
Is the problem solved after
replacing the high-voltage
power supply PCB?
Yes
Replace the high-
voltage power supply
PCB.
Main PCB
failure
6
Is the problem solved after
replacing the main PCB?
Yes
Replace the main PCB.
Laser unit
failure
7
Is the problem solved after
replacing the laser unit?
Yes
Replace the laser unit.