App.
4-52
Confidential
WSW48
(USB setup latency)
Selector
No.
Function
Setting and Specifications
1
|
5
Not used.
6
|
8
USB setup latency
No. 6 7 8
0
0
0
:
Default
period
0
0
1
:
Shorter
1
0
1
0
:
Longer
1
0
1
1
:
Longer
2
1
0
0
:
Longer
3
1
0
1
:
Longer
4
1
0
0
:
Shorter
2
1
1
1
:
Shorter
3
z
Selectors 6 through 8: USB setup latency
These selectors should not be disturbed.
WSW49
(End-of-copying beep and print in black)
Selector
No.
Function
Setting and Specifications
1
2
Not used.
3
End-of-copying beep
0: Yes
1: No
4
5
Command flag detection
time
No. 4 5
0
0
:
150
ms
0
1
:
350
ms
1
0
:
550
ms
1
1
:
750
ms
6
|
8
Not used.
z
Selectors 4 and 5: Command flag detection time
After receiving a command flag, the machine will wait for the command that should follow for the
time length specified by these selectors.