4.1.5. Left long-edge offset registration; 4.1.6. Top offset registration; Left long-edge offset registration - Page 47

Brother HL-4070CDW Command Reference Guide for Software Developers

Table of Contents

Technical Reference Guide
GLOSSARY
background image

 

CHAPTER 2 PCL - 27 

4.1.5.

 

Left long-edge offset registration 

Esc&

l

#U (27)(38)(108)#(85) 

<1Bh><26h><6Ch>#<55h> 

# stands for the distance in decipoints (1/720") that the left edge of the logical page is to be moved. 

 

Values for # may be in the range -32,767 to 32,767. 

 

The distance specified is relative to the logical page's current position. 

 

# can be positive or negative. Use a positive number to move the logical page to the right on the physical 
page, and a negative number to move it to the left. 

 

 

 

 

 

 

 

 

 

4.1.6.

 

Top offset registration 

Esc&

l

#Z (27)(38)(108)#(90) 

<1Bh><26h><6Ch>#<5Ah> 

# stands for the distance in decipoints (1/720") that the top edge of the logical page is to be moved. 

 

Values for # may be in the range -32,767 to 32,767. 

 

The distance specified is relative to the logical page's current position. 

 

# can be positive or negative. Use a positive number to move the logical page downwards on the physical 
page, and a negative number to move it upwards. 

 

 

 

 

 

 

 

 
 

Positive

Negative

Positive

Negative 

Detailed Information for Brother HL-4070CDW Command Reference Guide for Software Developers

Lists of information found in Brother HL-4070CDW Command Reference Guide for Software Developers - Page 47

  • 4.1.
  • 5. Left long-edge offset registration Esc&amp; l #U (27)(38)(108)#(85) &lt;1Bh&gt;&lt;26h&gt;&lt;6Ch&gt;#&lt;55h&gt; # stands for the distance in decipoints (1/720") that the left edge of the logical page is to be moved.
  • 67.  The distance specified is relative to the logical page's current position.
  • 4.1.
  • 6. Top offset registration Esc&amp; l #Z (27)(38)(108)#(90) &lt;1Bh&gt;&lt;26h&gt;&lt;6Ch&gt;#&lt;5Ah&gt; # stands for the distance in decipoints (1/720") that the top edge of the logical page is to be moved.
  • 67.  The distance specified is relative to the logical page's current position.

Related Documents for Brother HL-4070CDW Command Reference Guide for Software Developers