TCP/IP CONFIGURATION 10 - 12

YL4US_FAX2800MFC4800-FM5.5

You will then get the 

Local>

 prompt. Type 

SET IP ADDRESS 

ipaddress

, where 

ipaddress

 is the desired IP address you wish 

to assign to the print server (check with your network manager for the 
IP address to use). For example:

Local> SET IP ADDRESS 192.189.207.3

You will now need to set the subnet mask by typing 

SET IP SUBNET 

subnet mask

, where 

subnet mask

 is the desired subnet mask 

you wish to assign to the print server (check with your network 
manager for the subnet mask to use). For example:

Local> SET IP SUBNET 255.255.255.0

If you do not have any subnets, use one of the following default 
subnet masks:

255.255.255.0 

for class C networks

255.255.0.0 

for class B networks

255.0.0.0 

for class A networks

The leftmost group of digits in your IP address can identify the type 
of network you have. The value of this group ranges from 192 
through 255 for Class C networks (e.g., 192.189.207.3), 128 through 
191 for Class B networks (e.g.,128.10.1.30), and 1 through 127 for 
Class A networks (e.g., 13.27.7.1).

If you have a gateway (router), enter its address with the command 

SET IP ROUTER routeraddress

, where 

routeraddress

 is the 

desired IP address of the gateway you wish to assign to the print 
server. For example:

Local> SET IP ROUTER 192.189.207.1

Type 

SET IP METHOD STATIC

 to set the method of IP access 

configuration to static.

To verify that you have entered the IP information correctly, type 

SHOW IP

.

Type 

EXIT

 or CTR-D (i.e., hold down the control key and type "D") 

to end the remote console session.

Detailed Information for Brother HL-5070N Network User's Guide

Lists of information found in Brother HL-5070N Network User's Guide - Page 116

  • 5.5 You will then get the Local> prompt.
  • 92.189.
  • 7.3 You will now need to set the subnet mask by typing SET IP SUBNET subnet mask , where subnet mask is the desired subnet mask you wish to assign to the print server (check with your network manager for the subnet mask to use).
  • 55.255.
  • 55.0 If you do not have any subnets, use one of the following default subnet masks: 255.
  • 55.255.
  • 55.255.
  • 55.0.
  • 92.189.
  • 7.3), 128 through 191 for Class B networks (e.
  • 28.10.
  • 1.30), and 1 through 127 for Class A networks (e.
  • 13.27.
  • 7.1).
  • 92.189.
  • 7.1 Type SET IP METHOD STATIC to set the method of IP access configuration to static.

Related Documents for Brother HL-5070N Network User's Guide