APPENDIX

A-15

APPENDIX  6. NVRAM DEFAULT VALUE

The default values for the main items to be set in NVRAM are as follows;

Items

Descriptions

Timing of Drum LED ON

16,000 page

(Counted from the drum unit life.)

Development switching
timing

The developing bias is switched from 475V to 375V when
3,000 pages are printed.

(Counted from the number of the drum rotation in non-
continuous printing)

Fixing temperature

• 

Transparency: 163°C

• 

Thin paper: 183°C

• 

Regular paper: 195°C

• 

Thick paper: 215°C

• 

Thicker/Bond paper: 215°C (in non-continuous printing)

Smaller size mode

See 

APPENDIX 3 ‘PRINT SPEEDS WITH VARIOUS

SETTINGS’

.