APPENDIX
A-15
APPENDIX 6. NVRAM DEFAULT VALUE
The default values for the main items to be set in NVRAM are as follows;
Items
Descriptions
Timing of Drum LED ON
16,000 page
(Counted from the drum unit life.)
Development switching
timing
The developing bias is switched from 475V to 375V when
3,000 pages are printed.
(Counted from the number of the drum rotation in non-
continuous printing)
Fixing temperature
•
Transparency: 163°C
•
Thin paper: 183°C
•
Regular paper: 195°C
•
Thick paper: 215°C
•
Thicker/Bond paper: 215°C (in non-continuous printing)
Smaller size mode