PA - Plot absolute ; PR - Relative coordinate pen move ; PA [ X, Y [,...]] [;] - Page 175

Brother HL-7050N Command Reference Guide for Software Developers

Table of Contents

Technical Reference Guide
GLOSSARY
background image

 

CHAPTER 4 HP-GL/2 - 19 

PA - Plot absolute 

PA [ X, Y [,...]] [;] 

X ; X coordinate of the cursor movement destination 
Y ; Y coordinate of the cursor movement destination 

 

Coordinates are absolute values in user or current units. 

 

Whether used with or without parameters the command establishes absolute plotting as the plotting mode. 

 

The command moves the cursor to the specified coordinates, drawing straight lines, only when the pen is 
down. 

 

In symbol mode PA draws the specified symbol at each point in the parameter list. 

 

In polygon mode the specified coordinate pairs are placed in the polygon buffer. 

 

If an odd number of coordinates are specified,    the final (unpaired) coordinate is ignored. 

10 ' -- Plot Absolute -- 
20 WIDTH "LPT1:",255 
30 LPRINT CHR$(27);"E"; 
40 LPRINT CHR$(27);"%0B"; 
50 LPRINT "IN;SP1;"; 
60 LPRINT "PA2000,6000;PD0,6000,2000,7500,2000,6000;PU2500,6000;"; 
70 LPRINT "PAPD4500,6000,2500,7500,2500,6000;PU10365,500;"; 
80 LPRINT CHR$(27);"%0A"; 
90 LPRINT CHR$(27);"E"; 
100 END 

 

<Sample 24> 

 

PR - Relative coordinate pen move 

PR [X, Y [,...]] [;] 

X ; X coordinate of the cursor movement destination 
Y ; Y coordinate of the cursor movement destination 

 

Coordinates used are relative values in current units. 

 

Whether used with or without parameters the command establishes relative plotting as the plotting mode. 

 

The command moves the cursor to the specified coordinates, drawing straight lines, only when the pen is 
down. 

 

You can specify any number of coordinated pairs and plotting is performed in the order the coordinates are 
specified. 

 

In symbol mode PR draws the specified symbol at each point in the parameter list. 

 

In polygon mode the specified coordinate pairs are placed in the polygon buffer. 

 

If an odd number of coordinates are specified,    the final (unpaired) coordinate is ignored. 

10 ' - Plot Relative - 
20 WIDTH "LPT1:", 255 
20 LPRINT CHR$(27); "E"; 
30 LPRINT CHR$(27); "%0B"; 
40 LPRINT "IN;SP1;" 
50 LPRINT "PA5000,4500,;PDPR-2000,0,2000,2000,0,-2000;PU500,0;" 
60 LPRINT "PD2000,0,-2000,2000,0,-2000;PU;" 
70 LPRINT CHR$(27); "%0A"; 
80 LPRINT CHR$(27); "E"; 
90 END 

 