RR - Fill rectangle relative ; WG - Fill wedge ; RR X, Y[;] - Page 184

Brother HL-7050N Command Reference Guide for Software Developers

Table of Contents

Technical Reference Guide
GLOSSARY
background image

 

CHAPTER 4 HP-GL/2 - 28 

90 LPRINT "FT4,100,45;RA4250,4750;" 
100 LPRINT CHR$(27); "%0A"; 
110 LPRINT CHR$(27); "E"; 
120 END 
 
<Sample 34> 

 

RR - Fill rectangle relative 

RR X, Y[;] 

X ; X coordinate of opposite corner for the rectangle 
Y ; Y coordinate of opposite corner for the rectangle 

 

Coordinates relative to the current position in current units. 

 

Fill the rectangle formed by the current position and the opposite corner specified by X and Y. 

 

After plotting the cursor returns to its point of origin. 

 

Plotting is performed whether the pen is up or down. 

10 ' - Fill Relative Rectangle - 
20 WIDTH "LPT1:", 255 
30 LPRINT CHR$(27); "E"; 
40 LPRINT CHR$(27); "%0B"; 
50 LPRINT "IN;SP1;PA5000,4000;" 
60 LPRINT "FT1;RR750,750;" 
70 LPRINT "PR750,0;" 
80 LPRINT "FT3,100;RR750,750;" 
90 LPRINT "PR0,750;" 
100 LPRINT "FT2;RR750,750;" 
110 LPRINT "FT4,100,45;RR-750,750;" 
120 LPRINT CHR$(27); "%0A"; 
130 LPRINT CHR$(27); "E"; 
140 END  
 
<Sample 35> 

 

WG - Fill wedge 

WG 

r

,

q1

,

qc

(,

qd

)[;] 

r

 ; Radius in current units 

q1

 ; Start point angle 

qc

 ; Arc angle 

qd

 ; Chord angle 

 

Fill in a wedge centred on the current position with radius 

r

, start point angle 

q1

, arc angle 

qc

 and chord 

angle 

qd

 

After plotting, the cursor returns to its point of origin. 

 

Plotting is performed whether the pen is up or down. 

 

You should use this command with the type "isotropic".    Anisotropic type may make the wedge stretch. 

 

 

r

 specifies the radius of circle.    A positive value places the 0º reference point onto the positive x-axis and 

the negative value places it onto the negative x-axis. 

 

The value for 

q1

 is a clamped real number. 

 

q1

 specifies the wedge starting point related to the 0º reference point. 

 

When 

q1

 is positive, the positive direction of the X axis relative to the current position is set at 0 degrees and 

the start point is sought in the counterclockwise direction.    The opposite occurs when 

q1

 is negative: the 

negative X axis is set at 0 degrees and the start point is sought by going clockwise. 

 

qc

 specifies the angle of the wedge. 

 

The value for 

qc

 is a clamped real number. 

 

Plotting proceeds counterclockwise when 

qc

 is positive and clockwise when negative. 

 

The value for 

qd

 is a clamped real number. 

 

When 

qd

 is not specified, the chord angle is the default value ( 5 degrees ). 

Detailed Information for Brother HL-7050N Command Reference Guide for Software Developers

Related Documents for Brother HL-7050N Command Reference Guide for Software Developers