Symptom

Measures

Jump solenoid does not operate.

• Check to see if connection from the jump solenoid to connector P10 of

the head PCB is proper.

• Check the resistance value of the jump solenoid which does not

operate with the connector section. The normal resistance value is
approximately 185

.

  If it is faulty, replace the solenoid with a new one. In this case, the

head PCB may also be faulty. Also replace the head PCB with a
new one if it does not operate properly even after replacing the
solenoid.

• Replace the head PCB with a new one.

Wiper solenoid does not operate.

• Check to see if connection from the wiper solenoid to connector P11 of

the head PCB is proper.

• Check the resistance value of the wiper solenoid which does not

operate with the connector section. The normal resistance value is
approximately 28

.

  If it is faulty, replace the solenoid with a new one. In this case, the

head PCB may also be faulty. Also replace the head PCB with a
new one if it does not operate properly even after replacing the
solenoid.

• Replace the head PCB with a new one.

Pickker solenoid does not operate.

• Check to see if connection from the pickker solenoid to connector P8

of the head PCB is proper.

• Check the resistance value of the pickker solenoid which does not

operate with the connector section. The normal resistance value is
approximately 426

.

  If it is faulty, replace the solenoid with a new one. In this case, the

head PCB may also be faulty. Also replace the head PCB with a
new one if it does not operate properly even after replacing the
solenoid.

• Replace the head PCB with a new one.

Thread trimmer solenoid does not
operate.

• Check to see if connection from the thread trimmer solenoid to

connector P20 of the main PCB is proper.

• Check the resistance value of the thread trimmer solenoid which does

not operate with the connector section. The normal resistance value is
approximately 27

.

  If it is faulty, replace the solenoid with a new one. In this case, the

main PCB may also be faulty. Also replace the main PCB with a
new one if it does not operate properly even after replacing the
solenoid.

• Replace the main PCB with a new one.

Pressor foot solenoid does not
operate.

• Check to see if connection from the pressor foot solenoid to connector

P20 of the main PCB is proper.

• Check the resistance value of the pressor foot solenoid which does not

operate with the connector section. The normal resistance value is
approximately 80

.

  If it is faulty, replace the solenoid with a new one. In this case, the

main PCB may also be faulty. Also replace the mainPCB with a
new one if it does not operate properly even after replacing the
solenoid.

• Replace the main PCB with a new one.

Detailed Information for Brother BE-1201B-AC-PC User Manual

Lists of information found in Brother BE-1201B-AC-PC User Manual - Page 239

  • BE-1201B-AC-PC 12-7 Chapter 12 Troubleshooting Symptom Measures Jump solenoid does not operate.
  • Check to see if connection from the jump solenoid to connector P10 of the head PCB is proper.
  • Check the resistance value of the jump solenoid which does not operate with the connector section.
  • Replace the head PCB with a new one.
  • Check to see if connection from the wiper solenoid to connector P11 of the head PCB is proper.
  • Check the resistance value of the wiper solenoid which does not operate with the connector section.
  • Replace the head PCB with a new one.
  • Check to see if connection from the pickker solenoid to connector P8 of the head PCB is proper.
  • Check the resistance value of the pickker solenoid which does not operate with the connector section.
  • Replace the head PCB with a new one.
  • Check to see if connection from the thread trimmer solenoid to connector P20 of the main PCB is proper.
  • Check the resistance value of the thread trimmer solenoid which does not operate with the connector section.
  • Replace the main PCB with a new one.
  • Check to see if connection from the pressor foot solenoid to connector P20 of the main PCB is proper.
  • Check the resistance value of the pressor foot solenoid which does not operate with the connector section.
  • Replace the main PCB with a new one.