WSW15 

(REDIAL facility setting)

 

Selector 

No. 

Function 

Setting and Specifications 

 

Redial interval 

No. 1  2 
 

0 0 :  5 

minutes 

 

0 1 :  1 

minute 

 

1 0 :  2 

minutes 

 

1 1 :  3 

minutes 

No. of redialings 

No. 

3 4 5 6 

 

0 0 0 0  :  16 

times 

 

0 0 0 1  : 

  1 

times 

 

0 0 1 0  :  2 

times 

 

0 0 1 1  :  3 

times 

 

 

    |   

 

 

     | 

 

1 1 1 1  :  15 

times 

7 Not 

used. 

 

CRP option 

 0: Disable 

 

1: Enable 

 

  Selectors 1 through 6:  Redial interval and No. of redialings 

The machine redials by the number of times set by selectors 3 through 6 at intervals set by  
selectors 1 and 2. 

 Selector 

8:  CRP 

option 

If a command error occurs in the machine (calling station), the machine usually waits for three  
seconds and then makes a retry three times.  This CRP option is a request command that can be  
sent from the called station for requesting the calling station to retry the failed command  
immediately. 