App.
4-19
Confidential
WSW15
(REDIAL facility setting)
Selector
No.
Function
Setting and Specifications
1
2
Redial interval
No. 1 2
0 0 : 5
minutes
0 1 : 1
minute
1 0 : 2
minutes
1 1 : 3
minutes
3
|
6
No. of redialings
No.
3 4 5 6
0 0 0 0 : 16
times
0 0 0 1 :
1
times
0 0 1 0 : 2
times
0 0 1 1 : 3
times
|
|
1 1 1 1 : 15
times
7 Not
used.
8
CRP option
0: Disable
1: Enable
Selectors 1 through 6: Redial interval and No. of redialings
The machine redials by the number of times set by selectors 3 through 6 at intervals set by
selectors 1 and 2.
Selector
8: CRP
option
If a command error occurs in the machine (calling station), the machine usually waits for three
seconds and then makes a retry three times. This CRP option is a request command that can be
sent from the called station for requesting the calling station to retry the failed command
immediately.