App.
4-23
Confidential
WSW19
(Transmission speed setting)
Selector
No.
Function
Setting and Specifications
1
|
3
First transmission speed choice
for fallback
No.
1 2 3
No.
4 5 6
0 0 0
:
2,400 bps
0 0 1
:
4,800 bps
0 1 0
:
7,200 bps
4
|
6
Last transmission speed choice
for fallback
0 1 1
:
9,600 bps
1 0 0 :
12,000
bps
1 0 1 :
1 1 0 :
14,400
bps
1 1 1 :
7
V.34
mode
0: Permitted
1: Prohibited
8
V.17
mode
0: Permitted
1: Prohibited
NOTE:
Selector 7 takes effect only in models supporting V.34 mode.
Selectors 1 through 6: First and last choices of transmission speed for fallback
These selectors are used to set the MODEM speed range. With the first transmission speed choice
specified by selectors 1 through 3, the machine attempts to establish the transmission link via the
MODEM. If the establishment fails, the machine automatically steps down to the next lowest
speed and attempts to establish the transmission link again. The machine repeats this sequence
while stepping down the transmission speed to the last choice specified by selectors 4 through 6.
If the MODEM always falls back to a low transmission speed (e.g., 4,800 bps), set the first
transmission speed choice to the lower one (e.g., modify it from 12,000 bps to 7,200 bps) in order
to deactivate the high-speed MODEM function and reduce the training time for shorter
transmission time.