Setting and Specifications
1 Not
used.
2
3
Detection enabled time for CNG
and no tone
No. 2
3
0 0
: 40
sec.
0
1 :
0 sec. (No detection)
1
0 :
5 sec.
1 1
: 80
sec.
4
5
Not used.
6
Registration of station ID
0:
Permitted
1:
Prohibited
7
8
Tone sound monitoring
No. 7
8
0 X
: No
monitoring
1
0 :
Up to phase B at the
calling
station
only
1
1 :
All transmission phases
both at the calling and
called
stations
Selectors 2 and 3: Detection enabled time for CNG and no tone
After the line is connected via the external telephone or by picking up the handset of the machine,
the machine can detect a CNG signal or no tone for the time length specified by these selectors.
The setting specified by these selectors becomes effective only when selector 8 on WSW20 is set
to "1."
Selector 6: Registration of station ID
Setting this selector to "0" permits the registration of station ID for Austrian and Czech models.
Selectors 7 and 8: Tone sound monitoring