9. STANDARD ADJUSTMENTS
BAS-341F, 342F
40
(1)
(2)
(3)
(4)
(1)
9-12. Checking the input voltage
1. Turn on the power switch.
2. Press the menu switch (1) until the X-SCALE indicator (2) illuminates.
3. While pressing the TEST switch (3), press the R/W switch (4)
4. If the input voltage is normal, the input voltage conditions will be shown in the display as indicated at right.
200-V specifications
090 - 110
220-V specifications
100 - 120
"100" is displayed when the input voltage is 200 V.
230-V specifications
105 - 125
100-V, 380-V, 400-V
100 - 120
"110" is displayed when the input voltage is 100 V (for
100-V specs.), 380 V (for 380-V specs.).
5. Press the TEST switch (3) once more to return the display to the normal condition.
9-13. Clearing all memory settings
If the sewing machine stops operating normally, the cause may be that an incorrect memory setting may have been
made by means of the memory switch, for instance. In such cases, carry out the following procedure to clear the memory,
and also check the DIP switch settings.
While pressing the R/W switch (1), turn on the power. This will clear all of the memory setting.
Note
This operation causes memory switch settings to be returned to their initial settings, and also clears all contents of the
memory such as sewing datas.
1275S
1276S
1277S
1278S
1278S
1279S