App.
4-25
Confidential
Selectors 8: Limitation on CNG detection
If this selector is set to "1," the machine detects a CNG signal according to the condition preset by
selectors 2 and 3 on WSW18 after a line is connected. If it is set to "0," the machine detects a
CNG signal as long as the line is connected.
WSW21
(TAD setting 1
)
Selector
No.
Function
Setting and Specifications
1
|
5
Max. waiting time for voice
signal
No.
1 2 3 4 5
0 0 0 0 0 :
No
detection
0 0 0 0 1 :
1
sec.
0 0 0 1 0 :
2
sec.
0 0 0 1 1 :
3
sec.
|
|
0 1 0 0 0 :
8
sec.
|
|
1 1 1 1 1 :
31
sec.
6
7
Taping the call
No. 6 7
0 0 :
Enable (signaling for U.S.A.)
0 1 :
Enable (signaling for countries
except U.S.A.)
1 0 :
Enable (without signaling)
1
1
:
Disable
8
Erasure of message stored in
the memory after the message
transfer
0:
Yes 1:
No
NOTE:
Selectors 1 through 5 are applicable to models equipped with ICM recorders.
NOTE:
Selectors 6 and 7 are applicable to models with internal TADs.
NOTE:
Selector 8 is applicable to models equipped with TADs.
Selectors 1 through 5: Max. waiting time for voice signal
In the TAD mode, the machine waits for voice signal for the time length specified by these
selectors before it automatically shifts to the facsimile message receive mode or disconnects the
line.
Selectors 6 and 7: Taping the call
These selectors select whether or not to tape the call. Setting them to "1, 0" enables taping the call
without signaling to the calling station that the call is being taped.
Selector 8: Erasure of message stored in the memory after the message transfer
Setting this selector to "0" will erase the message recorded in the memory after the document
retrieval feature transfers the message.