App.
4-28
Confidential
WSW24
(TAD setting 2)
Selector
No.
Function
Setting and Specifications
1
2
Maximum OGM recording
time
No. 1 2
0
0
:
15
sec.
0
1
:
20
sec.
1
0
:
30
sec.
1
1
:
50
sec.
3
4
Time length from CML ON
to start of pseudo ring
backtone transmission
No. 3 4
0
0
:
4
sec.
0
1
:
3
sec.
1
0
:
2
sec.
1
1
:
1
sec.
5
|
8
Attenuator for playback of
ICM/OGM to the line
(Selectable from the range
of 0-15 dB)
0:
0 dB
1: 8 dB
0:
0 dB
1: 4 dB
0:
0 dB
1: 2 dB
0:
0 dB
1: 1 dB
Selectors 1 and 2: Maximum OGM recording time
These selectors set the allowable maximum recording time for an OGM.
Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission
These selectors set the length of time from CML-ON up to the start of pseudo ring backtone
transmission.
In models with OGM facilities, the settings made by these selectors also apply to the length of time
from CML-ON up to the start of OGM transmission.
Selectors 5 through 8:
Attenuator for playback of ICM/OGM to the line
Setting two or more selectors to "1" produces addition of attenuation assigned to each selector.
This setting is not limited by selector 8 on WSW23.