WSW41 (ON-duration of the scanning light source) - Page 309

Brother DCP7025 User Manual

2014 Dodge Charger SRT Owner Manual

Table of Contents

ALLFB SERVICE MANUAL
TABLE OF CONTENTS
background image

 App. 

4-46 

Confidential

 

WSW41 (ON-duration of the scanning light source) 

Selector 

No. 

Function 

Setting and Specifications 

ON-duration of the scanning 
light source at room 
temperature 
(Not used.) 

No. 1  2  3 

 0 

16 

hours 

 0 

24 

hours 

 0 

12 

hours 

 0 

: 8 

hours 

 1 

: 4 

hours 

 1 

: 2 

hours 

 1 

10 

minutes 

 1 

: 0 

minute 

4 Not 

used. 

 

8

 

Modem attenuator

 

No. 

5 6 7 8 

 

0 0 0 0 :  -10 

dBm 

 

0 0 0 1 :  -11 

dBm 

 

0 0 1 0 :  -12 

dBm 

 

0 0 1 1 :  -13 

dBm 

 

0 1 0 0 :  -14 

dBm 

 

 

    |   

 

 

     | 

 

1 1 1 1 :  -25 

dBm 

 

  Selectors 1 through 3: ON-duration of the scanning light source at room temperature (Not used.) 

If the scanning operation is started when the scanning light source is off, then it will come on for  
scanning.  These selectors determine how long the light source is ON after scanning. 
If these selectors are set to "1, 1, 1," the light source goes off immediately after the scanning  
sequence. 

  Selectors 5 through 8: Modem attenuator 

These selectors are used to adjust the transmitting level of the modem when the reception level at  
the remote station is improper due to line loss.  This function applies to super G3 protocol signals. 

 