Selector 

No. 

Function 

Setting and Specifications 

 

Frequency band selection (lower 
limit) for incoming calling signal 
(CI) 

No. 1  2 
 

0 0 :  13 

Hz 

 

0 1 :  15 

Hz 

 

1 0 :  23 

Hz 

 

1 1 :  20 

Hz 

Frequency band selection (upper 
limit) for incoming calling signal 
(CI) 

No. 3  4 
 

0 0 :  30 

Hz 

 

0 1 :  55 

Hz 

 

1 0 :  70 

Hz 

 

1 1 : 200 

Hz 

No. of rings in AUTO ANS mode 

No. 5 6 7 8 
 

0 0 0 0  :  Fixed 

to 

once 

 

0 0 0 1  :  Fixed 

to 

times 

 

0 0 1 0  :  Fixed 

to 

times 

 

0 0 1 1  :  Fixed 

to 

times 

 

0 1 0 0  :  1 

to 

times 

 

0 1 0 1  :  1 

to 

times 

 

0 1 1 0  :  1 

to 

times 

 

0 1 1 1  :  1 

to 

times 

 

1 0 0 0  :  2 

to 

times 

 

1 0 0 1  :  2 

to 

times 

 

1 0 1 0  :  2 

to 

times 

 

1 0 1 1  :  2 

to 

times 

 

1 1 0 0  :  1 

to 

10 

times 

 

1 1 0 1  :  2 

to 

10 

times 

 

1 1 1 0  :  3 

to 

times 

 

1 1 1 1  :  4 

to 

10 

times 

 

  Selectors 1 through 4:  Frequency band selection for incoming calling signal (CI) 

These selectors are used to select the frequency band of CI for activating the AUTO ANS facility. 
In the French models, if the user sets the PBX to OFF from the control panel, the setting made by  
selectors 1 and 2 will take no effect and the frequency's lower limit will be fixed to 32 Hz.  (Even  
if the setting made by these selectors does not apply, it will be printed on the configuration list.)

 

  Selectors 5 through 8:  No. of rings in AUTO ANS mode 