Max. detection period for incoming calling signal (CI) being OFF ; WSW12 ; OFF - Page 279

Brother DCP7025 User Manual

2014 Dodge Charger SRT Owner Manual

Table of Contents

ALLFB SERVICE MANUAL
TABLE OF CONTENTS
background image

 App. 

4-16 

Confidential

 

WSW12 

(Signal detection condition setting)

 

Selector 

No. 

Function 

Setting and Specifications 

 

Min. detection period required 
for interpreting incoming 
calling signal (CI) as OFF 

No. 1 

 

1500 ms  

 0 1  :  500 

ms 

 1 0  :  700 

ms 

 1 1  :  900 

ms 

 

Max. detection period for 
incoming calling signal (CI) 
being OFF 

No. 3 

 

  6 sec. 

 

  7 sec. 

 

  9 sec. 

 1 1  : 11 

sec. 

 

Min. detection period required 
for acknowledging incoming 
calling signal (CI) as ON 

No. 5 

 

800 ms (1000 ms*) 

 0 1  : 200 

ms 

 1 0  : 250 

ms 

 1 1  : 150 

ms 

Line connection timing                
(Not used.) 

 0: 

Ringer-OFF  1: 

Ringer-ON 

  

period 

(default) 

 

period 

8 Not 

used. 

 

*1000 ms in Chinese models. 

z

  Selectors 1 through 4:  Min. detection period required for interpreting incoming calling signal (CI) as 

OFF 
Max. detection period for incoming calling signal (CI) being OFF 

If the machine detects the OFF state of a CI signal for the period greater than the value set by  
selectors 1 and 2 and less than the value set by selectors 3 and 4, it interprets the CI signal as OFF. 

z

  Selectors 5 and 6:  Min. detection period required for acknowledging incoming calling signal (CI) as 

ON 

These selectors set the period required to make the machine acknowledge itself to be called.  That  
is, if the machine continuously detects a CI signal with the frequency set by selectors 1 through 4  
on WSW14 during the period set by these selectors 5 and 6, then it acknowledges the call. 

 