4-14 

Confidential

 

WSW10 

(Protocol definition 2)

 

Selector 

No. 

Function 

Setting and Specifications 

1 Not 

used. 

 

Time length from transmission 
of the last dial digit to CML 
ON 

 

0:  100 ms 

1:  50 ms 

Time length from CML ON to 
CNG transmission 

 

0:  2 sec. 

1:  4 sec. 

Time length from CML ON to 
CED transmission  (except for 
facsimile-to-telephone 
switching) 

 

0:  0.5 sec. 

1:  2 sec. 

No. of training retries 

No. 5  6 
 0 

time 

 0 

times 

 1 

times 

 1 

times 

MR  0: 

Allowed 

1: 

Not 

allowed 

Encoding system  
(Compression) 

MMR   0: 

Allowed  1: 

Not 

allowed 

 

  Selector 2:  Time length from transmission of the last dial digit to CML ON 

This selector sets the time length from when the machine transmits the last dial digit until the CML  
relay comes on. 

  Selector 3:  Time length from CML ON to CNG transmission 

This selector sets the time length until the machine transmits a CNG after it turns on the CML  
relay. 

  Selector 4:  Time length from CML ON to CED transmission 

This selector sets the time length until the machine transmits a CED after it turns on the CML  
relay. This setting does not apply to switching between facsimile and telephone. 

  Selectors 5 and 6:  No. of training retries 

These selectors set the number of training retries to be repeated before automatic fallback. 

  Selectors 7 and 8:  Encoding system (Compression) 

This selector determines whether or not to allow the use of the MR/MMR coding system. 

 

Detailed Information for Brother DCP7025 User Manual