telephone except in the external TAD mode or via the built-in telephone) ; telephone in the external TAD mode, via the built-in telephone in the TAD mode, or ; via the machine in the automatic reception of the F/T mode) - Page 293

Brother DCP7025 User Manual

2014 Dodge Charger SRT Owner Manual

Table of Contents

ALLFB SERVICE MANUAL
TABLE OF CONTENTS
background image

 App. 

4-30 

Confidential

 

WSW26 

(Function setting 4)

 

Selector 

No. 

Function 

Setting and Specifications 


Not used. 

 

Dialing during document 
reading into the temporary 
memory in in-memory message 
transmission 

0: Disable  1: Enable 


No. of CNG cycles to be 
detected 
(when the line is connected via 
the external telephone except in 
the external TAD mode or via 
the built-in telephone) 

No. 4 

 

0.5 

  (A) 

 

  (B) 

 

1.5 

  (C) 

 

  (D) 


No. of CNG cycles to be 
detected 
(when the line is connected via 
the external telephone in the 
external TAD mode, via the 
built-in telephone in the TAD 
mode, or via the machine in the 
automatic reception of the F/T 
mode) 

No. 6 

 0 

0 :  0.5 

 

 

(A) 

 0 

1 :  1 

 

 

(B) 

 1 

0 :  1.5 

 

 

(C) 

 1 

1 :  2 

 

 

(D) 

8 Not 

used. 

 

 

  Selector 3:  Dialing during document reading into the temporary memory in in-memory message 

transmission 

If this selector is set to "0," the machine waits for document reading into the memory to complete  
and then starts dialing.  This enables the machine to list the total number of pages in the header of  
the facsimile message. 

  Selectors 4 and 5:  No. of CNG cycles to be detected (when the line is connected via the external 

telephone except in the external TAD mode or via the built-in telephone) 

The machine interprets a CNG as an effective signal if it detects the CNG by the number of cycles  
specified by these selectors when the line is connected via the external telephone except in the  
external TAD mode or via the built-in telephone. 

  Selectors 6 and 7:  No. of CNG cycles to be detected (when the line is connected via the external 

telephone in the external TAD mode, via the built-in telephone in the TAD mode, or 
via the machine in the automatic reception of the F/T mode) 

The machine interprets a CNG as an effective signal if it detects the CNG by the number of cycles  
specified by these selectors when the line is connected via the external telephone in the external  
TAD mode, via the built-in telephone in the TAD mode, or via the machine in the automatic  
reception of the F/T mode. 