WSW35 - Page 302

Brother DCP7025 User Manual

2014 Dodge Charger SRT Owner Manual

Table of Contents

ALLFB SERVICE MANUAL
TABLE OF CONTENTS
background image

 App. 

4-39 

Confidential

 

WSW35 

(Function setting 13)

 

Selector 

No. 

Function 

Setting and Specifications 

Max. detection period of dial 
tone/busy tone during recording of 
ICM 

No. 1 2 3 4 

 

0 0 0 0 :  No 

detection 

 

0 0 0 1 :  1 

sec. 

 

0 0 1 0 :  2 

sec. 

 

0 1 0 0 :  4 

sec. 

 

 

 

 

 

   | 

 

1 1 1 1 :  15 

sec. 

Not used. 

 

NOTE:

  Selectors 1 through 4 are applicable to models equipped with internal TADs. 

  Selectors 1 through 4:  Max. detection period of dial tone/busy tone during recording of ICM 

If the machine (called station) detects dial tone or busy tone exceeding the detection level specified  
by selectors 1 through 3 on WSW30 for the period specified by these selectors, then it disconnects  
the line. 