App.
4-12
Confidential
WSW08
(Dial tone setting 2)
Selector
No.
Function
Setting and Specifications
1
|
3
1st dial tone detection time
length
No. 1 2 3
0 0 0 :
50
ms
0 0 1 :
210
ms
0 1 0 :
500
ms
0 1 1 :
800
ms
1 0 0 :
900
ms
1 0 1 :
1.5
sec.
1 1 0 :
2.0
sec.
1 1 1 :
2.5
sec.
4
5
Time-out length for 1st and
2nd dial tone detection
No. 4 5
0 0 : 10 sec.
0 1 : 20 sec.
1 0 : 15 sec.
1 1 : 30 sec.
6
|
8
Detection level of 1st dial
tone and busy tone before
dialing
No. 6 7 8
0
0 0 : -21 dBm
0
0 1 : -24 dBm
0
1 0 : -27 dBm
0
1 1 : -30 dBm
1
0 0 : -33 dBm
1
0 1 : -36 dBm
1
1 0 : -39 dBm
1
1 1 : -42 dBm
NOTE:
The WSW08 is not applicable in those countries where no dial tone detection is supported,
e.g., U.S.A.
Selectors 1 through 3: 1st dial tone detection time length
Upon detection of the 1st dial tone for the time length set by these selectors, the machine starts
dialing.
This setting is effective only when selectors 1 through 3 on WSW05 are set to "1,1,1."
Selectors 4 and 5: Time-out length for 1st and 2nd dial tone detection
These selectors set the time-out length for the 1st and 2nd dial tone detection so that the machine
waits dial tone input for the specified time length and disconnects itself from the line when no dial
tone is inputted.